Advanced modifications of 3-dimensional reconstructed CT images (3DRCTs) increase the accuracy of liver volume measurement - qualified by in vivo piglets' study

Yuh Hwan Liu, Xi-Zhang Lin, Bor-Shyang Sheu, Yung-Nien Sun, Hong-Ming Tsai, Ching Liang Shen

研究成果: Article

3 引文 (Scopus)

摘要

Three dimensional reconstruction of computerized tomography (3-DRCTs) images are studied and the defects are modified during volume calculation to improve the degree of accuracy. Liver volume is determinate by 3-DRCTs to document exact liver boundary in each film slice, to calculate the liver area in each film slice, to register and pile up each image for axilaization, to display the simulated 3D-reconstructed image and to measure the precise liver volume. During modifications of the steps, the deformable model is applied to document the exact boundary automatically.

原文English
頁(從 - 到)688-693
頁數6
期刊Biomedical Engineering - Applications, Basis and Communications
6
發行號5
出版狀態Published - 1994 一月 1

指紋

Volume measurement
Liver
Computerized tomography
Piles
Tomography
Defects

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Bioengineering

引用此文

@article{d7749aa688aa452d9272414251d234df,
title = "Advanced modifications of 3-dimensional reconstructed CT images (3DRCTs) increase the accuracy of liver volume measurement - qualified by in vivo piglets' study",
abstract = "Three dimensional reconstruction of computerized tomography (3-DRCTs) images are studied and the defects are modified during volume calculation to improve the degree of accuracy. Liver volume is determinate by 3-DRCTs to document exact liver boundary in each film slice, to calculate the liver area in each film slice, to register and pile up each image for axilaization, to display the simulated 3D-reconstructed image and to measure the precise liver volume. During modifications of the steps, the deformable model is applied to document the exact boundary automatically.",
author = "Liu, {Yuh Hwan} and Xi-Zhang Lin and Bor-Shyang Sheu and Yung-Nien Sun and Hong-Ming Tsai and Shen, {Ching Liang}",
year = "1994",
month = "1",
day = "1",
language = "English",
volume = "6",
pages = "688--693",
journal = "Biomedical Engineering - Applications, Basis and Communications",
issn = "1016-2372",
publisher = "World Scientific Publishing Co. Pte Ltd",
number = "5",

}

TY - JOUR

T1 - Advanced modifications of 3-dimensional reconstructed CT images (3DRCTs) increase the accuracy of liver volume measurement - qualified by in vivo piglets' study

AU - Liu, Yuh Hwan

AU - Lin, Xi-Zhang

AU - Sheu, Bor-Shyang

AU - Sun, Yung-Nien

AU - Tsai, Hong-Ming

AU - Shen, Ching Liang

PY - 1994/1/1

Y1 - 1994/1/1

N2 - Three dimensional reconstruction of computerized tomography (3-DRCTs) images are studied and the defects are modified during volume calculation to improve the degree of accuracy. Liver volume is determinate by 3-DRCTs to document exact liver boundary in each film slice, to calculate the liver area in each film slice, to register and pile up each image for axilaization, to display the simulated 3D-reconstructed image and to measure the precise liver volume. During modifications of the steps, the deformable model is applied to document the exact boundary automatically.

AB - Three dimensional reconstruction of computerized tomography (3-DRCTs) images are studied and the defects are modified during volume calculation to improve the degree of accuracy. Liver volume is determinate by 3-DRCTs to document exact liver boundary in each film slice, to calculate the liver area in each film slice, to register and pile up each image for axilaization, to display the simulated 3D-reconstructed image and to measure the precise liver volume. During modifications of the steps, the deformable model is applied to document the exact boundary automatically.

UR - http://www.scopus.com/inward/record.url?scp=0028530865&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028530865&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0028530865

VL - 6

SP - 688

EP - 693

JO - Biomedical Engineering - Applications, Basis and Communications

JF - Biomedical Engineering - Applications, Basis and Communications

SN - 1016-2372

IS - 5

ER -