An improved peak quantification algorithm for automatic heart rate measurements

Cheng Chi Tai, Jia Ren Chang Chien

研究成果: Conference contribution

11 引文 斯高帕斯(Scopus)

摘要

This paper proposes a new method improving the Peak Quantification Algorithm (PQA) introduced by Navakatikyan, et al. in measuring a human heart rate (HR). Experiments reveal that although the PQA can accurately measure the heart rates based on electrocardiogram (ECG) waveforms, this algorithm is too complex and uses too much memory, resulting in substantial reduction in accuracy when applied such algorithm to an embedded system. The proposed Improved-Peak Quantification Algorithm (Improved-PQA) can rapidly analyze the heartbeat waveforms and still accurately measure the heart rates even when it is adopted in an embedded system with a lower computational power and speed.

原文English
主出版物標題Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
頁面6623-6626
頁數4
出版狀態Published - 2005
事件2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005 - Shanghai, China