N2 - In this study, the performance of a high-temperature water gas shift reaction (WGSR) using a Fe-Cr catalyst along with a Pd alloy membrane was simulated by computational fluid dynamics (CFD). The influences of using Pd membranes, catalytic layer thickness ratio (R/R0), Reynolds number, and steam-to-CO ratio (S/C) on the reaction were investigated by comparing CO conversion and hydrogen recovery (HR). In the CFD simulation, one-tube and four-tube systems were simulated at 500 °C. This study also compared the performance between tandem and optimized configurations. The results show that the CO conversion can be improved up to 22.9% when the WGSR reactor system uses a Pd membrane compared to the system without a Pd membrane. The system has the best hydrogen recovery performance at S/C = 4 and R/R0 larger than 1.5. At Re=5, the optimized configuration for CO conversion has better performance when R/R0 is larger than 1.75. Compared to the tandem configuration, the optimized configuration also shows better performance for HR at every R/R0. The results indicate that a Pd membrane and optimized configuration can significantly improve CO conversion and that R/R0 and S/C optimization is very important for effective reactor performance.
AB - In this study, the performance of a high-temperature water gas shift reaction (WGSR) using a Fe-Cr catalyst along with a Pd alloy membrane was simulated by computational fluid dynamics (CFD). The influences of using Pd membranes, catalytic layer thickness ratio (R/R0), Reynolds number, and steam-to-CO ratio (S/C) on the reaction were investigated by comparing CO conversion and hydrogen recovery (HR). In the CFD simulation, one-tube and four-tube systems were simulated at 500 °C. This study also compared the performance between tandem and optimized configurations. The results show that the CO conversion can be improved up to 22.9% when the WGSR reactor system uses a Pd membrane compared to the system without a Pd membrane. The system has the best hydrogen recovery performance at S/C = 4 and R/R0 larger than 1.5. At Re=5, the optimized configuration for CO conversion has better performance when R/R0 is larger than 1.75. Compared to the tandem configuration, the optimized configuration also shows better performance for HR at every R/R0. The results indicate that a Pd membrane and optimized configuration can significantly improve CO conversion and that R/R0 and S/C optimization is very important for effective reactor performance.
UR - http://www.scopus.com/inward/record.url?scp=85171897029&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85171897029&partnerID=8YFLogxK
U2 - 10.1016/j.nexus.2023.100240
DO - 10.1016/j.nexus.2023.100240
M3 - Article
AN - SCOPUS:85171897029
SN - 2772-4271
VL - 12
JO - Energy Nexus
JF - Energy Nexus
M1 - 100240
ER -