Currently, a positive pressure blower or a negative pressure exhaust fan, employed in an air conditioning system, is driven by a constant speed AC motor, resulting in a constant air flow rate and a constant pressure. This paper presents an approach to compensate for the air resistance effect. A motor speed sensor is deployed between a brushless DC motor and a chamber, and the voltage drop across a current source is monitored using a digital voltmeter. Digital signal processing (DSP) is performed on the measured voltage signal using a microcontroller unit (MCU). Users can be notified instantly, once a threshold is reached, to clean up or replace a clogged air filter for energy efficiency improvement.

原文English
主出版物標題Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018
發行者Institute of Electrical and Electronics Engineers Inc.
頁面298-301
頁數4
ISBN(電子)9781538670361
DOIs
出版狀態Published - 2019 二月 19
事件4th International Symposium on Computer, Consumer and Control, IS3C 2018 - Taichung, Taiwan
持續時間: 2018 十二月 62018 十二月 8

出版系列

名字Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018

Conference

Conference4th International Symposium on Computer, Consumer and Control, IS3C 2018
國家Taiwan
城市Taichung
期間18-12-0618-12-08

指紋

Signal Detection
Signal detection
Conditioning
Air conditioning
Filter
Voltage
Digital voltmeters
Air filters
AC motors
Ventilation exhausts
Brushless DC motors
Blowers
DC Motor
Microcontroller
Microcontrollers
Air
Digital signal processing
Energy Efficiency
Flow Rate
Fans

All Science Journal Classification (ASJC) codes

  • Computer Networks and Communications
  • Control and Systems Engineering
  • Energy Engineering and Power Technology
  • Computer Science Applications
  • Control and Optimization
  • Signal Processing

引用此文

Chang, H. Y., Lin, C. Y., Chen, C-H., & Chan, C. C. (2019). An online filter clog rate signal detection mechanism in an air conditioning system. 於 Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018 (頁 298-301). [8644834] (Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IS3C.2018.00082
Chang, Hsi Yuan ; Lin, Chi Yuan ; Chen, Chin-Hsing ; Chan, Ching Chin. / An online filter clog rate signal detection mechanism in an air conditioning system. Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018. Institute of Electrical and Electronics Engineers Inc., 2019. 頁 298-301 (Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018).
@inproceedings{7a9db35362434bf38e9f7082c58ca393,
title = "An online filter clog rate signal detection mechanism in an air conditioning system",
abstract = "Currently, a positive pressure blower or a negative pressure exhaust fan, employed in an air conditioning system, is driven by a constant speed AC motor, resulting in a constant air flow rate and a constant pressure. This paper presents an approach to compensate for the air resistance effect. A motor speed sensor is deployed between a brushless DC motor and a chamber, and the voltage drop across a current source is monitored using a digital voltmeter. Digital signal processing (DSP) is performed on the measured voltage signal using a microcontroller unit (MCU). Users can be notified instantly, once a threshold is reached, to clean up or replace a clogged air filter for energy efficiency improvement.",
author = "Chang, {Hsi Yuan} and Lin, {Chi Yuan} and Chin-Hsing Chen and Chan, {Ching Chin}",
year = "2019",
month = "2",
day = "19",
doi = "10.1109/IS3C.2018.00082",
language = "English",
series = "Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "298--301",
booktitle = "Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018",
address = "United States",

}

Chang, HY, Lin, CY, Chen, C-H & Chan, CC 2019, An online filter clog rate signal detection mechanism in an air conditioning system. 於 Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018., 8644834, Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018, Institute of Electrical and Electronics Engineers Inc., 頁 298-301, 4th International Symposium on Computer, Consumer and Control, IS3C 2018, Taichung, Taiwan, 18-12-06. https://doi.org/10.1109/IS3C.2018.00082

An online filter clog rate signal detection mechanism in an air conditioning system. / Chang, Hsi Yuan; Lin, Chi Yuan; Chen, Chin-Hsing; Chan, Ching Chin.

Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018. Institute of Electrical and Electronics Engineers Inc., 2019. p. 298-301 8644834 (Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018).

研究成果: Conference contribution

TY - GEN

T1 - An online filter clog rate signal detection mechanism in an air conditioning system

AU - Chang, Hsi Yuan

AU - Lin, Chi Yuan

AU - Chen, Chin-Hsing

AU - Chan, Ching Chin

PY - 2019/2/19

Y1 - 2019/2/19

N2 - Currently, a positive pressure blower or a negative pressure exhaust fan, employed in an air conditioning system, is driven by a constant speed AC motor, resulting in a constant air flow rate and a constant pressure. This paper presents an approach to compensate for the air resistance effect. A motor speed sensor is deployed between a brushless DC motor and a chamber, and the voltage drop across a current source is monitored using a digital voltmeter. Digital signal processing (DSP) is performed on the measured voltage signal using a microcontroller unit (MCU). Users can be notified instantly, once a threshold is reached, to clean up or replace a clogged air filter for energy efficiency improvement.

AB - Currently, a positive pressure blower or a negative pressure exhaust fan, employed in an air conditioning system, is driven by a constant speed AC motor, resulting in a constant air flow rate and a constant pressure. This paper presents an approach to compensate for the air resistance effect. A motor speed sensor is deployed between a brushless DC motor and a chamber, and the voltage drop across a current source is monitored using a digital voltmeter. Digital signal processing (DSP) is performed on the measured voltage signal using a microcontroller unit (MCU). Users can be notified instantly, once a threshold is reached, to clean up or replace a clogged air filter for energy efficiency improvement.

UR - http://www.scopus.com/inward/record.url?scp=85063206621&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85063206621&partnerID=8YFLogxK

U2 - 10.1109/IS3C.2018.00082

DO - 10.1109/IS3C.2018.00082

M3 - Conference contribution

AN - SCOPUS:85063206621

T3 - Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018

SP - 298

EP - 301

BT - Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Chang HY, Lin CY, Chen C-H, Chan CC. An online filter clog rate signal detection mechanism in an air conditioning system. 於 Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018. Institute of Electrical and Electronics Engineers Inc. 2019. p. 298-301. 8644834. (Proceedings - 2018 International Symposium on Computer, Consumer and Control, IS3C 2018). https://doi.org/10.1109/IS3C.2018.00082