An ultrasonographic and anatomical study of carpal tunnel, with special emphasis on the safe zones in percutaneous release

  • T. C. Chern
  • , I. M. Jou
  • , W. C. Chen
  • , K. C. Wu
  • , C. J. Shao
  • , P. C. Shen

研究成果: Article同行評審

41   連結會在新分頁中打開 引文 斯高帕斯(Scopus)

摘要

We examined 40 wrists of 12 embalmed and eight fresh cadavers and defined the relative position of the flexor retinaculum to the neurovascular structure, ultrasonographic markers and safe zones by ultrasonography and anatomical dissection. Both longitudinal and transverse ultrasonographic sections clearly depicted the flexor retinaculum, neurovascular bundles, median nerve, flexor tendons and bony boundaries of the underlying joints. Topographic measurement showed [i] good correlation between the actual extent of the flexor retinaculum and the ultrasonographically determined distance between bony landmarks in all hands, and [ii] the widths and lengths of well-defined safe zones. A comparison study confirmed the accuracy of ultrasonography. We conclude that these ultrasonographic landmarks can locate the flexor retinaculum and facilitate safe and complete carpal tunnel release with open or minimally invasive techniques.

原文English
頁(從 - 到)66-71
頁數6
期刊Journal of Hand Surgery: European Volume
34
發行號1
DOIs
出版狀態Published - 2009

All Science Journal Classification (ASJC) codes

  • 手術

指紋

深入研究「An ultrasonographic and anatomical study of carpal tunnel, with special emphasis on the safe zones in percutaneous release」主題。共同形成了獨特的指紋。