TY - JOUR
T1 - Aortic dissection extending into the interventricular septum following redo aortic valve replacement surgery in a patient with Takayasu's arteritis
T2 - A rare case report
AU - Hu, Chan Han
AU - Chang, Chun Hao
AU - Tsai, Meng Ta
AU - Tsai, Wei Chuan
AU - Huang, Mu Shiang
N1 - Publisher Copyright:
© 2024 The Author(s).
PY - 2024/9/1
Y1 - 2024/9/1
N2 - Background: Takayasu's arteritis is an infrequent manifestation of vasculitis affecting the aorta and its primary branches with numerous symptoms. This report details a rare case wherein a patient developed interventricular septal dissection following aortic valve replacement. Case summary: A middle-Aged woman diagnosed with Takayasu's arteritis previously underwent aortic valve replacement with a mechanical valve owing to severe aortic regurgitation. Subsequently, she received a redo aortic valve replacement following an episode of prosthetic valve infective endocarditis with paravalvular leak. Heart failure symptoms emerged during follow-up, revealing aortic root dissection extending into the interventricular septum, causing significant prosthetic valve movement. A Trido Bentall operation and interventricular septum repair were performed, and the patient recovered smoothly. Discussion: Interventricular dissection, although uncommon, may be due to factors such as infection, myocardial infarction, congenital anomalies, trauma, or post-surgical shear stress. Timely diagnosis is imperative to prevent life-Threatening complications; surgery remains the primary treatment. The present case report describes a rare presentation that was successfully managed through a Bentall operation and underscores the necessity of prompt intervention in treating this condition.
AB - Background: Takayasu's arteritis is an infrequent manifestation of vasculitis affecting the aorta and its primary branches with numerous symptoms. This report details a rare case wherein a patient developed interventricular septal dissection following aortic valve replacement. Case summary: A middle-Aged woman diagnosed with Takayasu's arteritis previously underwent aortic valve replacement with a mechanical valve owing to severe aortic regurgitation. Subsequently, she received a redo aortic valve replacement following an episode of prosthetic valve infective endocarditis with paravalvular leak. Heart failure symptoms emerged during follow-up, revealing aortic root dissection extending into the interventricular septum, causing significant prosthetic valve movement. A Trido Bentall operation and interventricular septum repair were performed, and the patient recovered smoothly. Discussion: Interventricular dissection, although uncommon, may be due to factors such as infection, myocardial infarction, congenital anomalies, trauma, or post-surgical shear stress. Timely diagnosis is imperative to prevent life-Threatening complications; surgery remains the primary treatment. The present case report describes a rare presentation that was successfully managed through a Bentall operation and underscores the necessity of prompt intervention in treating this condition.
UR - http://www.scopus.com/inward/record.url?scp=85205391180&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85205391180&partnerID=8YFLogxK
U2 - 10.1093/ehjcr/ytae496
DO - 10.1093/ehjcr/ytae496
M3 - Article
AN - SCOPUS:85205391180
SN - 2514-2119
VL - 8
JO - European Heart Journal - Case Reports
JF - European Heart Journal - Case Reports
IS - 9
M1 - ytae496
ER -