Bearing capacity of free-rotating and restrained footings near slopes

Ching-Chuan Huang, Yue Wen Chen

研究成果: Article

2 引文 (Scopus)

摘要

Loading tests on model horizontal grounds and slopes are performed using a 100-mm-wide strip footing with restrained and free-rotation conditions. Test results reveal that complete restraint against rotations on the footing generates larger values of ultimate bearing capacity and deeper failure surfaces than those for footings with a free-rotation condition. This is true for horizontal and slanted grounds with various slope angles. Test results also reveal that for a vertically loaded footing, a major factor that influences the ultimate bearing capacity of the footing (q u ) is the load eccentricity (e c ) at the footing base. The influence of load inclination on the values of q u for free-rotating and fixed footings is minor because the load inclination angles measured during the loading tests were negligibly small. In the case of a footing placed on a slanted ground, a load eccentric toward the heel of the footing is associated with a larger value of q u than that for a load eccentric toward the toe of the footing when subjected to similar extents of load eccentricity. This observation suggests that the currently used formula for correcting load eccentricity (e c ) has to be updated in order to address the issue of increased q u induced by a load eccentricity toward the heel of the footing.

原文English
頁(從 - 到)1-10
頁數10
期刊Journal of GeoEngineering
14
發行號1
DOIs
出版狀態Published - 2019 一月 1

指紋

footing
Bearing capacity
bearing capacity
eccentricity
loading test
slope angle

All Science Journal Classification (ASJC) codes

  • Geotechnical Engineering and Engineering Geology

引用此文

@article{6271d862574d466ba57ed8687965586e,
title = "Bearing capacity of free-rotating and restrained footings near slopes",
abstract = "Loading tests on model horizontal grounds and slopes are performed using a 100-mm-wide strip footing with restrained and free-rotation conditions. Test results reveal that complete restraint against rotations on the footing generates larger values of ultimate bearing capacity and deeper failure surfaces than those for footings with a free-rotation condition. This is true for horizontal and slanted grounds with various slope angles. Test results also reveal that for a vertically loaded footing, a major factor that influences the ultimate bearing capacity of the footing (q u ) is the load eccentricity (e c ) at the footing base. The influence of load inclination on the values of q u for free-rotating and fixed footings is minor because the load inclination angles measured during the loading tests were negligibly small. In the case of a footing placed on a slanted ground, a load eccentric toward the heel of the footing is associated with a larger value of q u than that for a load eccentric toward the toe of the footing when subjected to similar extents of load eccentricity. This observation suggests that the currently used formula for correcting load eccentricity (e c ) has to be updated in order to address the issue of increased q u induced by a load eccentricity toward the heel of the footing.",
author = "Ching-Chuan Huang and Chen, {Yue Wen}",
year = "2019",
month = "1",
day = "1",
doi = "10.6310/jog.201903_14(1).1",
language = "English",
volume = "14",
pages = "1--10",
journal = "Journal of GeoEngineering",
issn = "1990-8326",
publisher = "Taiwan Geotechnical Society",
number = "1",

}

Bearing capacity of free-rotating and restrained footings near slopes. / Huang, Ching-Chuan; Chen, Yue Wen.

於: Journal of GeoEngineering, 卷 14, 編號 1, 01.01.2019, p. 1-10.

研究成果: Article

TY - JOUR

T1 - Bearing capacity of free-rotating and restrained footings near slopes

AU - Huang, Ching-Chuan

AU - Chen, Yue Wen

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Loading tests on model horizontal grounds and slopes are performed using a 100-mm-wide strip footing with restrained and free-rotation conditions. Test results reveal that complete restraint against rotations on the footing generates larger values of ultimate bearing capacity and deeper failure surfaces than those for footings with a free-rotation condition. This is true for horizontal and slanted grounds with various slope angles. Test results also reveal that for a vertically loaded footing, a major factor that influences the ultimate bearing capacity of the footing (q u ) is the load eccentricity (e c ) at the footing base. The influence of load inclination on the values of q u for free-rotating and fixed footings is minor because the load inclination angles measured during the loading tests were negligibly small. In the case of a footing placed on a slanted ground, a load eccentric toward the heel of the footing is associated with a larger value of q u than that for a load eccentric toward the toe of the footing when subjected to similar extents of load eccentricity. This observation suggests that the currently used formula for correcting load eccentricity (e c ) has to be updated in order to address the issue of increased q u induced by a load eccentricity toward the heel of the footing.

AB - Loading tests on model horizontal grounds and slopes are performed using a 100-mm-wide strip footing with restrained and free-rotation conditions. Test results reveal that complete restraint against rotations on the footing generates larger values of ultimate bearing capacity and deeper failure surfaces than those for footings with a free-rotation condition. This is true for horizontal and slanted grounds with various slope angles. Test results also reveal that for a vertically loaded footing, a major factor that influences the ultimate bearing capacity of the footing (q u ) is the load eccentricity (e c ) at the footing base. The influence of load inclination on the values of q u for free-rotating and fixed footings is minor because the load inclination angles measured during the loading tests were negligibly small. In the case of a footing placed on a slanted ground, a load eccentric toward the heel of the footing is associated with a larger value of q u than that for a load eccentric toward the toe of the footing when subjected to similar extents of load eccentricity. This observation suggests that the currently used formula for correcting load eccentricity (e c ) has to be updated in order to address the issue of increased q u induced by a load eccentricity toward the heel of the footing.

UR - http://www.scopus.com/inward/record.url?scp=85057369445&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85057369445&partnerID=8YFLogxK

U2 - 10.6310/jog.201903_14(1).1

DO - 10.6310/jog.201903_14(1).1

M3 - Article

AN - SCOPUS:85057369445

VL - 14

SP - 1

EP - 10

JO - Journal of GeoEngineering

JF - Journal of GeoEngineering

SN - 1990-8326

IS - 1