TY - JOUR
T1 - Biosorption and biotransformation behaviours of veterinary antibiotics under aerobic livestock wastewater treatment processes
AU - Chen, Chih Hung
AU - Chiou, Yi Chu
AU - Yang, Chao Lung
AU - Wang, Jen Hung
AU - Chen, Wan Ru
AU - Whang, Liang Ming
N1 - Funding Information:
The authors would like to acknowledge the analytical supports from SERLs of National Cheng Kung University ( NCKU ), the financial supports from the Ministry of Science and Technology of Taiwan ( NSC 102-2221-E-006 -007 -MY3 , MOST 102-2221-E-273-001-MY3 and MOST 106-2221-E-273-001-MY3 ) and partially financial supports from the Ministry of Education of Taiwan through the Top University Project Grant awarded to NCKU .
Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/9
Y1 - 2023/9
N2 - To study the fate of veterinary antibiotics released from swine wastewater treatment plants (SWTP), 10 antibiotics were investigated in each unit of a local SWTP periodically. Over a 14-month period of field investigation into target antibiotics, it was confirmed that tetracycline, chlortetracycline, sulfathiazole, and lincomycin were used in this SWTP, with their presence observed in raw manure. Most of these antibiotics could be effectively treated by aerobic activated sludge, except for lincomycin, which was still detected in the effluent, with a maximum concentration of 1506 μg/L. In addition, the potential for removing antibiotics was evaluated using lab-scale aerobic sequencing batch reactors (SBRs) that were dosed with high concentrations of antibiotics. The SBR results, however, showed that both sulfonamides and macrolides, as well as lincomycin, can achieve 100% removal in lab-scale aerobic SBRs within 7 days. This reveals that the potential removal of those antibiotics in field aeration tanks can be facilitated by providing suitable conditions, such as adequate dissolved oxygen, pH, and retention time. Furthermore, the biosorption of target antibiotics was also confirmed in the abiotic sorption batch tests. Biotransformation and hydrolysis were identified as the dominant mechanism for removing negatively charged sulfonamides and positively charged antibiotics (macrolides and lincomycin) in SBRs. This is due to their relatively low sorption affinity (resulting in negligible to 20% removal) onto activated sludge in abiotic sorption tests. On the other hand, tetracyclines exhibited significant sorption behavior both onto activated sludge and onto soluble organic matters in swine wastewater supernatant, accounting for 70%–91% and 21%–94% of removal within 24 h, respectively. S-shape sorption isotherms with saturation were observed when high amounts of tetracyclines were spiked into sludge, with equilibrium concentrations ranging from 0.4 to 65 mg/L. Therefore, the sorption of tetracyclines onto activated sludge was governed by electrostatic interaction rather than hydrophobic partition. This resulted in a saturated sorption capacity (Qmax) of 17,263 mg/g, 1637 mg/g, and 641.7 mg/g for OTC, TC, and CTC, respectively.
AB - To study the fate of veterinary antibiotics released from swine wastewater treatment plants (SWTP), 10 antibiotics were investigated in each unit of a local SWTP periodically. Over a 14-month period of field investigation into target antibiotics, it was confirmed that tetracycline, chlortetracycline, sulfathiazole, and lincomycin were used in this SWTP, with their presence observed in raw manure. Most of these antibiotics could be effectively treated by aerobic activated sludge, except for lincomycin, which was still detected in the effluent, with a maximum concentration of 1506 μg/L. In addition, the potential for removing antibiotics was evaluated using lab-scale aerobic sequencing batch reactors (SBRs) that were dosed with high concentrations of antibiotics. The SBR results, however, showed that both sulfonamides and macrolides, as well as lincomycin, can achieve 100% removal in lab-scale aerobic SBRs within 7 days. This reveals that the potential removal of those antibiotics in field aeration tanks can be facilitated by providing suitable conditions, such as adequate dissolved oxygen, pH, and retention time. Furthermore, the biosorption of target antibiotics was also confirmed in the abiotic sorption batch tests. Biotransformation and hydrolysis were identified as the dominant mechanism for removing negatively charged sulfonamides and positively charged antibiotics (macrolides and lincomycin) in SBRs. This is due to their relatively low sorption affinity (resulting in negligible to 20% removal) onto activated sludge in abiotic sorption tests. On the other hand, tetracyclines exhibited significant sorption behavior both onto activated sludge and onto soluble organic matters in swine wastewater supernatant, accounting for 70%–91% and 21%–94% of removal within 24 h, respectively. S-shape sorption isotherms with saturation were observed when high amounts of tetracyclines were spiked into sludge, with equilibrium concentrations ranging from 0.4 to 65 mg/L. Therefore, the sorption of tetracyclines onto activated sludge was governed by electrostatic interaction rather than hydrophobic partition. This resulted in a saturated sorption capacity (Qmax) of 17,263 mg/g, 1637 mg/g, and 641.7 mg/g for OTC, TC, and CTC, respectively.
UR - https://www.scopus.com/pages/publications/85161649151
UR - https://www.scopus.com/pages/publications/85161649151#tab=citedBy
U2 - 10.1016/j.chemosphere.2023.139034
DO - 10.1016/j.chemosphere.2023.139034
M3 - Article
C2 - 37277000
AN - SCOPUS:85161649151
SN - 0045-6535
VL - 335
JO - Chemosphere
JF - Chemosphere
M1 - 139034
ER -