TY - JOUR
T1 - Carbodiimide-derivatized hyaluronic acid surface modification of lyophilized flexor tendon
T2 - A biomechanical study in a canine in vitro model
AU - Ikeda, Jun
AU - Zhao, Chunfeng
AU - Sun, Yu Long
AU - An, Kai Nan
AU - Amadio, Peter C.
N1 - Funding Information:
This study was supported by a grant from the Musculoskeletal Transplant Foundation (MTF), which was used for salaries, materials, and supplies.
PY - 2010/2/1
Y1 - 2010/2/1
N2 - Background: Intrasynovial grafts are the ideal solution to replace defects in intrasynovial flexor tendons, but autologous graft sources are rarely available. The purpose of the present study was to test the hypotheses that an intrasynovial tendon prepared with repetitive freeze-thaw cycles and lyophilization (as a means of reducing immunogenicity) has increased frictional force (gliding resistance) in comparison with fresh intrasynovial tendons and that a lyophilized intrasynovial flexor tendon that is modified with carbodiimide-derivatized hyaluronic acid and gelatin has decreased frictional force in comparison with untreated lyophilized tendons. Methods: Thirty-six flexor digitorum profundus tendons from the second and fifth digits of canine hind paws were randomly assigned to three groups. Twelve tendons were immediately assessed both mechanically and morphologically and served as the normal tendon group. The other twenty-four tendons were prepared with repetitive freeze-thaw cycles and lyophilization and were randomly assigned to two groups, including one group in which the tendons were treated with carbodiimide- derivatized hyaluronic acid and gelatin and one group in which the tendons were not treated. The frictional force was measured during 1000 cycles of simulated flexion-extension motion in all tendons, and the mean frictional forces were compared. The tendons were then observed with use of transmitted light microscopy for residual hyaluronic acid on the tendon surface, and the smoothness of the surface was evaluated with use of scanning electron microscopy. Results: The frictional force after lyophilization was significantly increased by 104.9% after the first cycle and by 99.5% after 1000 cycles in comparison with the normal tendon (p < 0.05). The frictional force of the lyophilized tendons after treatment with carbodiimide-derivatized hyaluronic acid and gelatin was not significantly different from that of normal tendons. The untreated lyophilized tendon surfaces were observed on scanning electron microscopy to be rough in appearance, whereas the normal surface and the surface treated with carbodiimide-derivatized hyaluronic acid and gelatin were smooth, with residual hyaluronic acid present on the gliding surface. Conclusions: Lyophilization alters tendon surface morphology and increases tendon frictional force. Surface modification with carbodiimide-derivatized hyaluronic acid and gelatin can mitigate this adverse effect. Clinical Relevance: Tendon surface modification with carbodiimide-derivatized hyaluronic acid and gelatin can improve the gliding ability of lyophilized flexor tendons and therefore may improve the utility of lyophilized tendon allografts as a tendon graft substitute.
AB - Background: Intrasynovial grafts are the ideal solution to replace defects in intrasynovial flexor tendons, but autologous graft sources are rarely available. The purpose of the present study was to test the hypotheses that an intrasynovial tendon prepared with repetitive freeze-thaw cycles and lyophilization (as a means of reducing immunogenicity) has increased frictional force (gliding resistance) in comparison with fresh intrasynovial tendons and that a lyophilized intrasynovial flexor tendon that is modified with carbodiimide-derivatized hyaluronic acid and gelatin has decreased frictional force in comparison with untreated lyophilized tendons. Methods: Thirty-six flexor digitorum profundus tendons from the second and fifth digits of canine hind paws were randomly assigned to three groups. Twelve tendons were immediately assessed both mechanically and morphologically and served as the normal tendon group. The other twenty-four tendons were prepared with repetitive freeze-thaw cycles and lyophilization and were randomly assigned to two groups, including one group in which the tendons were treated with carbodiimide- derivatized hyaluronic acid and gelatin and one group in which the tendons were not treated. The frictional force was measured during 1000 cycles of simulated flexion-extension motion in all tendons, and the mean frictional forces were compared. The tendons were then observed with use of transmitted light microscopy for residual hyaluronic acid on the tendon surface, and the smoothness of the surface was evaluated with use of scanning electron microscopy. Results: The frictional force after lyophilization was significantly increased by 104.9% after the first cycle and by 99.5% after 1000 cycles in comparison with the normal tendon (p < 0.05). The frictional force of the lyophilized tendons after treatment with carbodiimide-derivatized hyaluronic acid and gelatin was not significantly different from that of normal tendons. The untreated lyophilized tendon surfaces were observed on scanning electron microscopy to be rough in appearance, whereas the normal surface and the surface treated with carbodiimide-derivatized hyaluronic acid and gelatin were smooth, with residual hyaluronic acid present on the gliding surface. Conclusions: Lyophilization alters tendon surface morphology and increases tendon frictional force. Surface modification with carbodiimide-derivatized hyaluronic acid and gelatin can mitigate this adverse effect. Clinical Relevance: Tendon surface modification with carbodiimide-derivatized hyaluronic acid and gelatin can improve the gliding ability of lyophilized flexor tendons and therefore may improve the utility of lyophilized tendon allografts as a tendon graft substitute.
UR - http://www.scopus.com/inward/record.url?scp=77950463375&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950463375&partnerID=8YFLogxK
U2 - 10.2106/JBJS.H.01641
DO - 10.2106/JBJS.H.01641
M3 - Article
C2 - 20124066
AN - SCOPUS:77950463375
SN - 0021-9355
VL - 92
SP - 388
EP - 395
JO - Journal of Bone and Joint Surgery
JF - Journal of Bone and Joint Surgery
IS - 2
ER -