TY - JOUR
T1 - Contraction behaviors of dental composite restorations - Finite element investigation with DIC validation
AU - Chuang, Shu Fen
AU - Chang, Chih Han
AU - Chen, Terry Yuan Fang
N1 - Funding Information:
The authors state that there are no conflicts of interest in this work. This study was supported by Research Grant 96-2320-B-006-034-MY3 from the National Science Council, Taiwan .
PY - 2011/11
Y1 - 2011/11
N2 - The objective of this study was to examine the effects of cavity configuration on the polymerization shrinkage and stress of light-cured composite restorations by combining local strain measurement and a finite element analysis (FEA). Dental mesio-occluso-distal cavities of various widths and depths (each for 2 vs. 4 mm), representing different configuration factors, were prepared on extracted molars. The displacements of the bonded tooth cusps and cavity floors, caused by polymerization shrinkage of composite restorations, were assessed utilizing a digital-image-correlation (DIC) technique. The cervical marginal microleakage was investigated by examining the resin replicas of these restorations under SEM. The local material properties of the polymerized composite along the curing depth were defined by the nanoindentation test and applied in the subsequent FEA. In the FEA, four models were generated to correspond with the experimental restorations. In the DIC measurement results, the 4(w)×4(D)mm cavity presented the greatest values of inward displacements at the cusp and floor. The cavity depth, rather than the cavity width, was found to significantly correlate to the floor deformation, the location of shrinkage centers, and also the cervical microleakage ratio. The FEA simulation results showed that the 2(w)×4(D)mm cavity presented the maximal von Mises and principal stress located respectively on the cervical margins and cavity floor. Additional safety factor analysis showed a high risk of bond failure over the cavity floor in the 4-mm deep cavity. With the experimental validation, the simulation revealed that the cavity depth was significant to the formation of contraction stress and the incidence of interfacial debonding.
AB - The objective of this study was to examine the effects of cavity configuration on the polymerization shrinkage and stress of light-cured composite restorations by combining local strain measurement and a finite element analysis (FEA). Dental mesio-occluso-distal cavities of various widths and depths (each for 2 vs. 4 mm), representing different configuration factors, were prepared on extracted molars. The displacements of the bonded tooth cusps and cavity floors, caused by polymerization shrinkage of composite restorations, were assessed utilizing a digital-image-correlation (DIC) technique. The cervical marginal microleakage was investigated by examining the resin replicas of these restorations under SEM. The local material properties of the polymerized composite along the curing depth were defined by the nanoindentation test and applied in the subsequent FEA. In the FEA, four models were generated to correspond with the experimental restorations. In the DIC measurement results, the 4(w)×4(D)mm cavity presented the greatest values of inward displacements at the cusp and floor. The cavity depth, rather than the cavity width, was found to significantly correlate to the floor deformation, the location of shrinkage centers, and also the cervical microleakage ratio. The FEA simulation results showed that the 2(w)×4(D)mm cavity presented the maximal von Mises and principal stress located respectively on the cervical margins and cavity floor. Additional safety factor analysis showed a high risk of bond failure over the cavity floor in the 4-mm deep cavity. With the experimental validation, the simulation revealed that the cavity depth was significant to the formation of contraction stress and the incidence of interfacial debonding.
UR - http://www.scopus.com/inward/record.url?scp=81255127397&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=81255127397&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2011.07.014
DO - 10.1016/j.jmbbm.2011.07.014
M3 - Article
C2 - 22098914
AN - SCOPUS:81255127397
SN - 1751-6161
VL - 4
SP - 2138
EP - 2149
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
IS - 8
ER -