Cooling performance of flat plate heat pipes with different liquid filling ratios

Jung Shun Chen, Jung Hua Chou

研究成果: Article同行評審

47 引文 斯高帕斯(Scopus)

摘要

The effects of liquid filling ratios and leakage on the cooling performance of flat plate heat pipes (FPHPs) were examined experimentally in this study. With the size of 150 mm × 50 mm × 2.5 mm for all Al 6061 FPHPs filled with acetone (99.87% pure), the results showed that the one with the liquid filling ratio of 25% performed thermally the best. The corresponding maximum heat transport capability, minimum thermal resistance, and maximum effective thermal conductivity were about 47 W, 0.254 K/W, and 3150 W/m K, respectively. In contrast, improper vacuum and leakage would decrease the maximum thermal conductivities greatly to about 200-306 W/m K and 164 W/m K, respectively. The latter was similar to that of an aluminum block and performed the worst among all FPHPs. This situation should be avoided or carefully assessed as the maximum effective thermal conductivity decreased from the best by a factor of about 19.2.

原文English
頁(從 - 到)874-882
頁數9
期刊International Journal of Heat and Mass Transfer
77
DOIs
出版狀態Published - 2014 十月

All Science Journal Classification (ASJC) codes

  • 凝聚態物理學
  • 機械工業
  • 流體流動和轉移過程

指紋

深入研究「Cooling performance of flat plate heat pipes with different liquid filling ratios」主題。共同形成了獨特的指紋。