TY - JOUR
T1 - Designing a molecularly imprinted polymer as an artificial receptor for the specific recognition of creatinine in serums
AU - Hsieh, Ryh Yaw
AU - Tsai, Hsuan Ang
AU - Syu, Mei Jywan
PY - 2006/3
Y1 - 2006/3
N2 - In this study, molecularly imprinted polymers (MIP) synthesized from two different functional monomers, β-cyclodextrin (β-CD) and 4-vinylpyridine (4-Vpy), were prepared. The crosslinkers used for these two monomers were epichlorohydrin (EPI) and divinylbenzene (DVB), respectively. It was attempted to adsorb the target molecule, creatinine, from its mixture solutions. A proper molar ratio of monomer/crosslinker for the preparation of the imprinted poly(β-CD) was 1:10. Between both polymers mentioned above, the affinity of the imprinted poly(4-Vpy-co-DVB) towards creatinine was comparably superior. The imprinted poly(4-Vpy-co-DVB) for creatinine could reach a specific binding ratio of 3.11. The imprinted poly(4-Vpy-co-DVB) was further utilized to bind creatinine from human serum samples. The binding capacity of the imprinted poly(4-Vpy-co-DVB) for creatinine from the serum samples was plotted against the creatinine concentration. From the correlation, the feasibility of the imprinted poly(4-Vpy-co-DVB) thus prepared for the target analyte, creatinine, was experimentally confirmed.
AB - In this study, molecularly imprinted polymers (MIP) synthesized from two different functional monomers, β-cyclodextrin (β-CD) and 4-vinylpyridine (4-Vpy), were prepared. The crosslinkers used for these two monomers were epichlorohydrin (EPI) and divinylbenzene (DVB), respectively. It was attempted to adsorb the target molecule, creatinine, from its mixture solutions. A proper molar ratio of monomer/crosslinker for the preparation of the imprinted poly(β-CD) was 1:10. Between both polymers mentioned above, the affinity of the imprinted poly(4-Vpy-co-DVB) towards creatinine was comparably superior. The imprinted poly(4-Vpy-co-DVB) for creatinine could reach a specific binding ratio of 3.11. The imprinted poly(4-Vpy-co-DVB) was further utilized to bind creatinine from human serum samples. The binding capacity of the imprinted poly(4-Vpy-co-DVB) for creatinine from the serum samples was plotted against the creatinine concentration. From the correlation, the feasibility of the imprinted poly(4-Vpy-co-DVB) thus prepared for the target analyte, creatinine, was experimentally confirmed.
UR - http://www.scopus.com/inward/record.url?scp=28744452455&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=28744452455&partnerID=8YFLogxK
U2 - 10.1016/j.biomaterials.2005.09.024
DO - 10.1016/j.biomaterials.2005.09.024
M3 - Article
C2 - 16236356
AN - SCOPUS:28744452455
SN - 0142-9612
VL - 27
SP - 2083
EP - 2089
JO - Biomaterials
JF - Biomaterials
IS - 9
ER -