T1 - Development and validation of an HPLC-UV method for the analysis of methoxyamine using 4-(diethylamino)benzaldehyde as a derivatizing agent
AU - Liao, Yu Chieh
AU - Yang, Shuming
AU - Syu, Mei Jywan
AU - Xu, Yan
PY - 2005/9/15
Y1 - 2005/9/15
N2 - Methoxyamine (MX) is a potential new anti-cancer drug. In this paper, a quantitative HPLC-UV method for MX using 4-(diethylamino)benzaldehyde (DEAB) as a derivatizing agent has been developed and validated. The studies showed that MX reacts with DEAB under acidic conditions to form protonated 4-(diethylamino)benzaldehyde o-methyloxime (DBMOH+). The equilibrium between DBMOH+ and its conjugate base 4-(diethylamino)benzaldehyde o-methyloxime (DBMO) is affected by both buffer concentration and organic solvent content in the solution. The method developed uses a reversed phase C18 column for the separation of MX derivatives, an internal standard benzil for method calibration, and a UV detector at a wavelength of 310 nm for analyte detection. The MX derivatives can be resolved in ca. 20 min. The method has a linear calibration range from 0.100 to 10.0 μM with a correlation coefficient of 0.999 for MX and a detection limit of 5 pmol with a 50 μl sample size. The intra-assay and inter-assay precision expressed in terms of percent relative standard deviation were ≤5 and 8%; and the intra-assay and inter-assay accuracy defined as the measured value divided by the accepted value multiplied by 100% were 94.2-100 and 92.6-111%, respectively. This method may be used for the analysis of MX in pharmaceutical preparations.
AB - Methoxyamine (MX) is a potential new anti-cancer drug. In this paper, a quantitative HPLC-UV method for MX using 4-(diethylamino)benzaldehyde (DEAB) as a derivatizing agent has been developed and validated. The studies showed that MX reacts with DEAB under acidic conditions to form protonated 4-(diethylamino)benzaldehyde o-methyloxime (DBMOH+). The equilibrium between DBMOH+ and its conjugate base 4-(diethylamino)benzaldehyde o-methyloxime (DBMO) is affected by both buffer concentration and organic solvent content in the solution. The method developed uses a reversed phase C18 column for the separation of MX derivatives, an internal standard benzil for method calibration, and a UV detector at a wavelength of 310 nm for analyte detection. The MX derivatives can be resolved in ca. 20 min. The method has a linear calibration range from 0.100 to 10.0 μM with a correlation coefficient of 0.999 for MX and a detection limit of 5 pmol with a 50 μl sample size. The intra-assay and inter-assay precision expressed in terms of percent relative standard deviation were ≤5 and 8%; and the intra-assay and inter-assay accuracy defined as the measured value divided by the accepted value multiplied by 100% were 94.2-100 and 92.6-111%, respectively. This method may be used for the analysis of MX in pharmaceutical preparations.
UR - http://www.scopus.com/inward/record.url?scp=23944433177&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=23944433177&partnerID=8YFLogxK
U2 - 10.1016/j.jpba.2005.04.035
DO - 10.1016/j.jpba.2005.04.035
M3 - Article
C2 - 15951147
AN - SCOPUS:23944433177
SN - 0731-7085
VL - 39
SP - 724
EP - 729
JO - Journal of Pharmaceutical and Biomedical Analysis
JF - Journal of Pharmaceutical and Biomedical Analysis
IS - 3-4
ER -