Development of a FPGA-based quantitative ultrasound system for assessing stress-strain properties of Achilles tendon

Guan Chun Chen, Jian Xing Wu, Yi Chun Du, Chia Hung Lin, Pei Jarn Chen, Tainsong Chen

研究成果: Conference contribution

1 引文 斯高帕斯(Scopus)

摘要

Achilles tendon (AT) is the most fragile and vulnerable part in human body. Stress-strain properties and shape changing such as cross-sectional area variations of this tendon are important biomechanical properties used clinically for assessing and monitoring surgical repair or postoperative healing progress. However, so far, there are few methods for non-invasively, precisely and quantitatively assessing in vivo AT mechanism. In this study, we develop a quantitative ultrasound system (QUS) based on FPGA aiming at estimating stress-strain properties of AT via evaluating the broadband ultrasound attenuation (BUA) parameter upon different levels of applied stress on the AT. Twenty fresh ATs of hind porcine trotters were procured from a local abattoir, and were preloaded for 30 cycles with a cyclic loading ranging from 0 to 300 N. The loading force pulled along the tendon fibers, and the changes of AT cross-sectional area were acquired by ultrasound transducer implemented in the palmardorsal direction which was perpendicular to the tendon fibers. BUA has been widely used to estimate the broadband ultrasonic attenuation (dB MHz-1) by calculating the slope of a linear regression fit to the attenuation against frequency plot within a frequency range. The tendons were then strained from 1 to 400 N with single steps of 50 N, and the measurements were repeated for ten times following calculating the average slope of BUA to reduce the interference of noise. Results showed that as the tendon tissue was stretched orthogonally to the beam axis, BUA coefficient decreased linearly with increasing stress (R-square =0.89). This indicated that the BUA coefficient is a potentially useful parameter for quantitative characterization of ATs. The FPGA system proposed for measuring tendon thickness using QUS technique is an easy and objective method to precisely evaluate the tissue thickness, providing a new way for AT to implement high-speed online diagnosis.

原文English
主出版物標題IEEE International Ultrasonics Symposium, IUS
發行者IEEE Computer Society
頁面2430-2433
頁數4
ISBN(電子)9781479970490
DOIs
出版狀態Published - 2014 十月 20
事件2014 IEEE International Ultrasonics Symposium, IUS 2014 - Chicago, United States
持續時間: 2014 九月 32014 九月 6

出版系列

名字IEEE International Ultrasonics Symposium, IUS
ISSN(列印)1948-5719
ISSN(電子)1948-5727

Other

Other2014 IEEE International Ultrasonics Symposium, IUS 2014
國家/地區United States
城市Chicago
期間14-09-0314-09-06

All Science Journal Classification (ASJC) codes

  • 聲學與超音波

指紋

深入研究「Development of a FPGA-based quantitative ultrasound system for assessing stress-strain properties of Achilles tendon」主題。共同形成了獨特的指紋。

引用此