Development of an FPW biosensor with low insertion loss and high fabrication yield for detection of carcinoembryonic antigen

Je Wei Lan, I. Yu Huang, Yu Cheng Lin, Chang Yu Lin, Jian Lin Chen, Chia Hsu Hsieh

研究成果: Article同行評審

7 引文 斯高帕斯(Scopus)

摘要

In the last two decades, various flexural plate-wave (FPW)-based biosensors with low phase velocity, low operation frequency, high sensitivity, and short response time, have been developed. However, conventional FPW transducers have low fabrication yield because controlling the thickness of silicon/isolation/metal/piezoelectric multilayer floating thin-plate is difficult. Additionally, conventional FPW devices usually have high insertion loss because of wave energy dissipation to the silicon substrate or outside area of the output interdigital transducers (IDTs). These two disadvantages hinder the application of FPW devices. To reduce the high insertion loss of FPW devices, we designed two focus-type IDTs (fan-shaped and circular, respectively) that can effectively confine the launched wave energy, and adopted a focus-type silicon-grooved reflective grating structure (RGS) that can reduce the wave propagation loss. To accurately control the thickness of the silicon thin-plate and substantially improve the fabrication yield of FPW transducers, a 60 °C/27 °C two-step anisotropic wet etching process was developed. Compared with conventional FPW devices (with parallel-type IDTs and without RGS), the proposed FPW devices have lower insertion loss (36.04 dB) and higher fabrication yield (63.88%). Furthermore, by using cystamine-based self-assembled monolayer (SAM) nanotechnology, we used the improved FPW device to develop a novel FPW-based carcinoembryonic antigen (CEA) biosensor for detection of colorectal cancer, and this FPW-CEA biosensor has a low detection limit (5 ng/mL), short response time (<10 min), high sensitivity (60.16–70.06 cm2/g), and high sensing linearity (R-square = 0.859–0.980).

原文English
文章編號1729
期刊Sensors (Switzerland)
16
發行號11
DOIs
出版狀態Published - 2016 十一月

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry
  • Biochemistry
  • Atomic and Molecular Physics, and Optics
  • Instrumentation
  • Electrical and Electronic Engineering

指紋 深入研究「Development of an FPW biosensor with low insertion loss and high fabrication yield for detection of carcinoembryonic antigen」主題。共同形成了獨特的指紋。

引用此