Development of tactile sensors for simultaneous, detection of normal and shear stresses

Yu Ming Huang, Nan-Chyuan Tsai, Jing Yao Lai

研究成果: Article

23 引文 (Scopus)

摘要

A novel tactile sensor is analyzed and verified by intensive experiments. By using micro-cantilever beams, on which the strain gauge layers (Pt/Ti) are deposited, the corresponding induced strains can be detected and converted into electric resistance change, with respect to either applied normal stress or shear stress. The four micro-cantilever beams are allocated in the fashion such that any adjacent beams are perpendicular to each other to decouple any potential measurement discrepancy due to non-ideal orthogonality. In addition, the micro-cantilever beams are curled beforehand so that they can concurrently detect normal stress and shear stress. To be protected from being damaged by strong stress, the curled cantilever beams are embedded by elastomer material. Therefore, the micro-tactile sensor can detect normal stress up to 250 kPa and shear stress up to 35 kPa. Besides, since the elastomer is made of PDMS, which is of high biocompatibility, the tactile sensor can be used to directly contact with human body. By taking the design and fabrication parameters into account, the curled micro-cantilever beams, which are composed by four layers: polymer/Pt/Ti/Si, can be produced with high yield rate. Finally, the efficacy of the tactile sensor is verified by experiments via a micro-manipulator, a high-resolution microscope and a force sensor for calibration.

原文English
頁(從 - 到)189-195
頁數7
期刊Sensors and Actuators, A: Physical
159
發行號2
DOIs
出版狀態Published - 2010 一月 1

指紋

Cantilever beams
shear stress
Shear stress
cantilever beams
Elastomers
Sensors
elastomers
Strain gages
Biocompatibility
Manipulators
Polymers
Microscopes
strain gages
orthogonality
human body
biocompatibility
Experiments
Calibration
Fabrication
manipulators

All Science Journal Classification (ASJC) codes

  • Electronic, Optical and Magnetic Materials
  • Instrumentation
  • Condensed Matter Physics
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electrical and Electronic Engineering

引用此文

@article{7af2c12a11dc48a1a256c074cfa04b99,
title = "Development of tactile sensors for simultaneous, detection of normal and shear stresses",
abstract = "A novel tactile sensor is analyzed and verified by intensive experiments. By using micro-cantilever beams, on which the strain gauge layers (Pt/Ti) are deposited, the corresponding induced strains can be detected and converted into electric resistance change, with respect to either applied normal stress or shear stress. The four micro-cantilever beams are allocated in the fashion such that any adjacent beams are perpendicular to each other to decouple any potential measurement discrepancy due to non-ideal orthogonality. In addition, the micro-cantilever beams are curled beforehand so that they can concurrently detect normal stress and shear stress. To be protected from being damaged by strong stress, the curled cantilever beams are embedded by elastomer material. Therefore, the micro-tactile sensor can detect normal stress up to 250 kPa and shear stress up to 35 kPa. Besides, since the elastomer is made of PDMS, which is of high biocompatibility, the tactile sensor can be used to directly contact with human body. By taking the design and fabrication parameters into account, the curled micro-cantilever beams, which are composed by four layers: polymer/Pt/Ti/Si, can be produced with high yield rate. Finally, the efficacy of the tactile sensor is verified by experiments via a micro-manipulator, a high-resolution microscope and a force sensor for calibration.",
author = "Huang, {Yu Ming} and Nan-Chyuan Tsai and Lai, {Jing Yao}",
year = "2010",
month = "1",
day = "1",
doi = "10.1016/j.sna.2010.03.032",
language = "English",
volume = "159",
pages = "189--195",
journal = "Sensors and Actuators, A: Physical",
issn = "0924-4247",
publisher = "Elsevier",
number = "2",

}

Development of tactile sensors for simultaneous, detection of normal and shear stresses. / Huang, Yu Ming; Tsai, Nan-Chyuan; Lai, Jing Yao.

於: Sensors and Actuators, A: Physical, 卷 159, 編號 2, 01.01.2010, p. 189-195.

研究成果: Article

TY - JOUR

T1 - Development of tactile sensors for simultaneous, detection of normal and shear stresses

AU - Huang, Yu Ming

AU - Tsai, Nan-Chyuan

AU - Lai, Jing Yao

PY - 2010/1/1

Y1 - 2010/1/1

N2 - A novel tactile sensor is analyzed and verified by intensive experiments. By using micro-cantilever beams, on which the strain gauge layers (Pt/Ti) are deposited, the corresponding induced strains can be detected and converted into electric resistance change, with respect to either applied normal stress or shear stress. The four micro-cantilever beams are allocated in the fashion such that any adjacent beams are perpendicular to each other to decouple any potential measurement discrepancy due to non-ideal orthogonality. In addition, the micro-cantilever beams are curled beforehand so that they can concurrently detect normal stress and shear stress. To be protected from being damaged by strong stress, the curled cantilever beams are embedded by elastomer material. Therefore, the micro-tactile sensor can detect normal stress up to 250 kPa and shear stress up to 35 kPa. Besides, since the elastomer is made of PDMS, which is of high biocompatibility, the tactile sensor can be used to directly contact with human body. By taking the design and fabrication parameters into account, the curled micro-cantilever beams, which are composed by four layers: polymer/Pt/Ti/Si, can be produced with high yield rate. Finally, the efficacy of the tactile sensor is verified by experiments via a micro-manipulator, a high-resolution microscope and a force sensor for calibration.

AB - A novel tactile sensor is analyzed and verified by intensive experiments. By using micro-cantilever beams, on which the strain gauge layers (Pt/Ti) are deposited, the corresponding induced strains can be detected and converted into electric resistance change, with respect to either applied normal stress or shear stress. The four micro-cantilever beams are allocated in the fashion such that any adjacent beams are perpendicular to each other to decouple any potential measurement discrepancy due to non-ideal orthogonality. In addition, the micro-cantilever beams are curled beforehand so that they can concurrently detect normal stress and shear stress. To be protected from being damaged by strong stress, the curled cantilever beams are embedded by elastomer material. Therefore, the micro-tactile sensor can detect normal stress up to 250 kPa and shear stress up to 35 kPa. Besides, since the elastomer is made of PDMS, which is of high biocompatibility, the tactile sensor can be used to directly contact with human body. By taking the design and fabrication parameters into account, the curled micro-cantilever beams, which are composed by four layers: polymer/Pt/Ti/Si, can be produced with high yield rate. Finally, the efficacy of the tactile sensor is verified by experiments via a micro-manipulator, a high-resolution microscope and a force sensor for calibration.

UR - http://www.scopus.com/inward/record.url?scp=77954312361&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954312361&partnerID=8YFLogxK

U2 - 10.1016/j.sna.2010.03.032

DO - 10.1016/j.sna.2010.03.032

M3 - Article

AN - SCOPUS:77954312361

VL - 159

SP - 189

EP - 195

JO - Sensors and Actuators, A: Physical

JF - Sensors and Actuators, A: Physical

SN - 0924-4247

IS - 2