TY - JOUR
T1 - Direct measurements of local bed shear stress in the presence of pressure gradients
AU - Pujara, Nimish
AU - Liu, Philip L.F.
N1 - Funding Information:
The authors gratefully acknowledge the support of the National Science Foundation (CMMI-1041541), the help of Paul Charles, Tim Brock, and John Powers in construction of the shear plate sensor, and the help of Yong Sung Park in the initial design stage. The authors would like to thank Edwin A. Cowen for helpful discussions. The authors would also like to thank two anonymous reviewers for their comments that helped to improve the manuscript. Any opinions and comments are those of the authors and do not necessarily reflect the views of the sponsors.
PY - 2014/7
Y1 - 2014/7
N2 - This paper describes the development of a shear plate sensor capable of directly measuring the local mean bed shear stress in small-scale and large-scale laboratory flumes. The sensor is capable of measuring bed shear stress in the range ± 200 Pa with an accuracy up to ± 1 %. Its size, 43 mm in the flow direction, is designed to be small enough to give spatially local measurements, and its bandwidth, 75 Hz, is high enough to resolve time-varying forcing. Typically, shear plate sensors are restricted to use in zero pressure gradient flows because secondary forces on the edge of the shear plate caused by pressure gradients can introduce large errors. However, by analysis of the pressure distribution at the edges of the shear plate in mild pressure gradients, we introduce a new methodology for correcting for the pressure gradient force. The developed sensor includes pressure tappings to measure the pressure gradient in the flow, and the methodology for correction is applied to obtain accurate measurements of bed shear stress under solitary waves in a small-scale wave flume. The sensor is also validated by measurements in a turbulent flat plate boundary layer in open channel flow.
AB - This paper describes the development of a shear plate sensor capable of directly measuring the local mean bed shear stress in small-scale and large-scale laboratory flumes. The sensor is capable of measuring bed shear stress in the range ± 200 Pa with an accuracy up to ± 1 %. Its size, 43 mm in the flow direction, is designed to be small enough to give spatially local measurements, and its bandwidth, 75 Hz, is high enough to resolve time-varying forcing. Typically, shear plate sensors are restricted to use in zero pressure gradient flows because secondary forces on the edge of the shear plate caused by pressure gradients can introduce large errors. However, by analysis of the pressure distribution at the edges of the shear plate in mild pressure gradients, we introduce a new methodology for correcting for the pressure gradient force. The developed sensor includes pressure tappings to measure the pressure gradient in the flow, and the methodology for correction is applied to obtain accurate measurements of bed shear stress under solitary waves in a small-scale wave flume. The sensor is also validated by measurements in a turbulent flat plate boundary layer in open channel flow.
UR - http://www.scopus.com/inward/record.url?scp=84902300999&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84902300999&partnerID=8YFLogxK
U2 - 10.1007/s00348-014-1767-8
DO - 10.1007/s00348-014-1767-8
M3 - Article
AN - SCOPUS:84902300999
SN - 0723-4864
VL - 55
JO - Experiments in Fluids
JF - Experiments in Fluids
IS - 7
M1 - 1767
ER -