TY - JOUR
T1 - Does using high-tensile strength tape improve the fixation strength in tendon graft fixation with needleless suture wrapping techniques compared to a suture?
AU - Hong, Chih Kai
AU - Kuan, Fa Chuan
AU - Hsu, Kai Lan
AU - Chen, Yueh
AU - Chuang, Hao Chun
AU - Chiang, Chen Hao
AU - Su, Wei Ren
N1 - Publisher Copyright:
© The Author(s) 2020.
PY - 2020
Y1 - 2020
N2 - Purpose: To compare the biomechanical properties of a high-tensile strength suture and high-tensile strength tape in tendon graft fixation using two needleless suture wrapping techniques, the modified Prusik knot and modified rolling hitch. Methods: Two needleless suture wrapping techniques, the modified rolling hitch (MR) and modified Prusik knot (MP), were utilized. Meanwhile, two kinds of suture materials, a No. 2 braided nonabsorbable high-strength suture (S) and a 1.3 mm high-tensile strength tape (T), were used. A total of 40 porcine tendons were used, which were randomly divided into four groups. Each group was assigned to one of the following groups: MRS, MRT, MPS, and MPT. Each specimen was pretensioned to 100 N for three cycles, cyclically loaded from 50 to 200 N for 200 cycles, and finally loaded to failure. Results: The MRT group (34.1 ± 3.5%) had a significantly higher value compared with the MRS (29.7 ± 2.3%), MPS (27.1 ± 3.6%) and MPT (29.5 ± 4.0%) groups in term of elongation after cyclic loadings (p = 0.002). In terms of ultimate failure load, there were no significant differences in the MRS (401 ± 27 N), MRT (380 ± 27 N), MPS (398 ± 44 N) and MPT (406 ± 49 N) values (p = 0.539). All specimens failed due to suture breakage at the knots. Conclusion: Compared with the high-tensile strength suture, using the high-tensile strength tape lead to greater elongation after cyclic loading when the modified rolling hitch was used. No differences in terms of elongation after cyclic loading and load to failure were found between the high-tensile strength suture and tape using the modified Prusik knot.
AB - Purpose: To compare the biomechanical properties of a high-tensile strength suture and high-tensile strength tape in tendon graft fixation using two needleless suture wrapping techniques, the modified Prusik knot and modified rolling hitch. Methods: Two needleless suture wrapping techniques, the modified rolling hitch (MR) and modified Prusik knot (MP), were utilized. Meanwhile, two kinds of suture materials, a No. 2 braided nonabsorbable high-strength suture (S) and a 1.3 mm high-tensile strength tape (T), were used. A total of 40 porcine tendons were used, which were randomly divided into four groups. Each group was assigned to one of the following groups: MRS, MRT, MPS, and MPT. Each specimen was pretensioned to 100 N for three cycles, cyclically loaded from 50 to 200 N for 200 cycles, and finally loaded to failure. Results: The MRT group (34.1 ± 3.5%) had a significantly higher value compared with the MRS (29.7 ± 2.3%), MPS (27.1 ± 3.6%) and MPT (29.5 ± 4.0%) groups in term of elongation after cyclic loadings (p = 0.002). In terms of ultimate failure load, there were no significant differences in the MRS (401 ± 27 N), MRT (380 ± 27 N), MPS (398 ± 44 N) and MPT (406 ± 49 N) values (p = 0.539). All specimens failed due to suture breakage at the knots. Conclusion: Compared with the high-tensile strength suture, using the high-tensile strength tape lead to greater elongation after cyclic loading when the modified rolling hitch was used. No differences in terms of elongation after cyclic loading and load to failure were found between the high-tensile strength suture and tape using the modified Prusik knot.
UR - http://www.scopus.com/inward/record.url?scp=85096556352&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85096556352&partnerID=8YFLogxK
U2 - 10.1177/2309499020971865
DO - 10.1177/2309499020971865
M3 - Article
C2 - 33225808
AN - SCOPUS:85096556352
SN - 1022-5536
VL - 28
JO - Journal of Orthopaedic Surgery
JF - Journal of Orthopaedic Surgery
IS - 3
ER -