Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants

Yu Chuan Tseng, Chun Chan Ting, Ju Hui Wu, Hong Sen Chen, Chun Ming Chen

研究成果: Article

摘要

Purpose: The aim of this study was to evaluate the pullout strength of 3 different orthodontic mini implants. Materials and Methods: Twenty-seven mini implants (diameter: 2 mm, length: 7 mm) were implanted into artificial bone (Sawbones; Pacific Research Laboratories Inc.) at depths of 3, 4, and 5 mm. The insertion torque (IT), resonance frequency (RF), pullout strength (PS), and anchor length (AL) were measured. One-way analysis of variance with Tukey honest significant difference (HSD) postcomparison were used to detect intergroup differences. The null hypothesis was that IT, RF, and PS would significantly correlate in the same brand. Results: In the implantation depths (ID) (5 and 4 mm), IT of Types C (16.67 and 14.33 N·cm) and Type B (14 and 13.33 N·cm) were significantly higher than Type A (10.33 and 9.33 N·cm). Type A had a largest AL and PS at the IDs (5 and 4 mm). In the IDs (3 mm), PS was no different. Type C had no correlation among the RF, IT, and PS. Therefore, null hypothesis was rejected. Conclusion: AL exerted crucial effects on the PS of the mini implants.

原文English
頁(從 - 到)553-558
頁數6
期刊Implant Dentistry
26
發行號4
DOIs
出版狀態Published - 2017 八月 1

指紋

Torque
Orthodontics
Analysis of Variance
Bone and Bones
Research

All Science Journal Classification (ASJC) codes

  • Oral Surgery

引用此文

Tseng, Yu Chuan ; Ting, Chun Chan ; Wu, Ju Hui ; Chen, Hong Sen ; Chen, Chun Ming. / Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants. 於: Implant Dentistry. 2017 ; 卷 26, 編號 4. 頁 553-558.
@article{35a8d93d26d748fd859cf111834c0a13,
title = "Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants",
abstract = "Purpose: The aim of this study was to evaluate the pullout strength of 3 different orthodontic mini implants. Materials and Methods: Twenty-seven mini implants (diameter: 2 mm, length: 7 mm) were implanted into artificial bone (Sawbones; Pacific Research Laboratories Inc.) at depths of 3, 4, and 5 mm. The insertion torque (IT), resonance frequency (RF), pullout strength (PS), and anchor length (AL) were measured. One-way analysis of variance with Tukey honest significant difference (HSD) postcomparison were used to detect intergroup differences. The null hypothesis was that IT, RF, and PS would significantly correlate in the same brand. Results: In the implantation depths (ID) (5 and 4 mm), IT of Types C (16.67 and 14.33 N·cm) and Type B (14 and 13.33 N·cm) were significantly higher than Type A (10.33 and 9.33 N·cm). Type A had a largest AL and PS at the IDs (5 and 4 mm). In the IDs (3 mm), PS was no different. Type C had no correlation among the RF, IT, and PS. Therefore, null hypothesis was rejected. Conclusion: AL exerted crucial effects on the PS of the mini implants.",
author = "Tseng, {Yu Chuan} and Ting, {Chun Chan} and Wu, {Ju Hui} and Chen, {Hong Sen} and Chen, {Chun Ming}",
year = "2017",
month = "8",
day = "1",
doi = "10.1097/ID.0000000000000579",
language = "English",
volume = "26",
pages = "553--558",
journal = "Implant Dentistry",
issn = "1056-6163",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants. / Tseng, Yu Chuan; Ting, Chun Chan; Wu, Ju Hui; Chen, Hong Sen; Chen, Chun Ming.

於: Implant Dentistry, 卷 26, 編號 4, 01.08.2017, p. 553-558.

研究成果: Article

TY - JOUR

T1 - Effect of Anchor Length on the Pullout Strength of Palatal Mini Implants

AU - Tseng, Yu Chuan

AU - Ting, Chun Chan

AU - Wu, Ju Hui

AU - Chen, Hong Sen

AU - Chen, Chun Ming

PY - 2017/8/1

Y1 - 2017/8/1

N2 - Purpose: The aim of this study was to evaluate the pullout strength of 3 different orthodontic mini implants. Materials and Methods: Twenty-seven mini implants (diameter: 2 mm, length: 7 mm) were implanted into artificial bone (Sawbones; Pacific Research Laboratories Inc.) at depths of 3, 4, and 5 mm. The insertion torque (IT), resonance frequency (RF), pullout strength (PS), and anchor length (AL) were measured. One-way analysis of variance with Tukey honest significant difference (HSD) postcomparison were used to detect intergroup differences. The null hypothesis was that IT, RF, and PS would significantly correlate in the same brand. Results: In the implantation depths (ID) (5 and 4 mm), IT of Types C (16.67 and 14.33 N·cm) and Type B (14 and 13.33 N·cm) were significantly higher than Type A (10.33 and 9.33 N·cm). Type A had a largest AL and PS at the IDs (5 and 4 mm). In the IDs (3 mm), PS was no different. Type C had no correlation among the RF, IT, and PS. Therefore, null hypothesis was rejected. Conclusion: AL exerted crucial effects on the PS of the mini implants.

AB - Purpose: The aim of this study was to evaluate the pullout strength of 3 different orthodontic mini implants. Materials and Methods: Twenty-seven mini implants (diameter: 2 mm, length: 7 mm) were implanted into artificial bone (Sawbones; Pacific Research Laboratories Inc.) at depths of 3, 4, and 5 mm. The insertion torque (IT), resonance frequency (RF), pullout strength (PS), and anchor length (AL) were measured. One-way analysis of variance with Tukey honest significant difference (HSD) postcomparison were used to detect intergroup differences. The null hypothesis was that IT, RF, and PS would significantly correlate in the same brand. Results: In the implantation depths (ID) (5 and 4 mm), IT of Types C (16.67 and 14.33 N·cm) and Type B (14 and 13.33 N·cm) were significantly higher than Type A (10.33 and 9.33 N·cm). Type A had a largest AL and PS at the IDs (5 and 4 mm). In the IDs (3 mm), PS was no different. Type C had no correlation among the RF, IT, and PS. Therefore, null hypothesis was rejected. Conclusion: AL exerted crucial effects on the PS of the mini implants.

UR - http://www.scopus.com/inward/record.url?scp=85016129245&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85016129245&partnerID=8YFLogxK

U2 - 10.1097/ID.0000000000000579

DO - 10.1097/ID.0000000000000579

M3 - Article

C2 - 28350585

AN - SCOPUS:85016129245

VL - 26

SP - 553

EP - 558

JO - Implant Dentistry

JF - Implant Dentistry

SN - 1056-6163