TY - JOUR
T1 - Efficacy of radiofrequency ablation for twin-reversed arterial perfusion sequence
AU - Lee, Hanmin
AU - Wagner, Amy J.
AU - Sy, Edgar
AU - Ball, Robert
AU - Feldstein, Vickie A.
AU - Goldstein, Ruth B.
AU - Farmer, Diana L.
PY - 2007/5
Y1 - 2007/5
N2 - Objective: We report our experience in the treatment of patients with twin-reversed arterial perfusion (TRAP) sequence using radiofrequency ablation to stop perfusion to the acardiac twin and protect the pump twin. Study Design: An IRB approved retrospective review of all patients (n = 29) who underwent percutaneous radiofrequency ablation of an acardiac twin, using ultrasound guidance and either a 14 or 17 gauge radiofrequency needle for twin-reversed arterial perfusion sequence, from 1998 to 2005, was performed by review of hospital and outpatient medical records. Results: The outcomes of all 29 of the patients treated with radiofrequency ablation are known. Twenty-six of the patients had monochorionic-diamniotic pregnancies, whereas 2 had monochorionic-monoamniotic pregnancies. One patient had a triplet pregnancy with a monochorionic-diamniotic pair with TRAP sequence. Overall, 25 of 29 pump twins survived (86%), delivering at a mean gestational age of 34.6 weeks. Survival was 24 of 26 (92%) in monochorionic-diamniotic pregnancies with a mean gestational age of 35.6 weeks. Two women in our early experience sustained thermal injuries from the site of grounding pads. Conclusion: Radiofrequency ablation of the acardiac twin effectively protects the pump twin from high-output cardiac failure and death. Greater than 90% survival can be achieved in monochorionic-diamniotic pregnancies complicated by TRAP sequence with a mean gestation age at time of delivery close to term. Our limited experience in cases of monochorionic-monoamniotic TRAP sequence does not allow the determination of efficacy in this group.
AB - Objective: We report our experience in the treatment of patients with twin-reversed arterial perfusion (TRAP) sequence using radiofrequency ablation to stop perfusion to the acardiac twin and protect the pump twin. Study Design: An IRB approved retrospective review of all patients (n = 29) who underwent percutaneous radiofrequency ablation of an acardiac twin, using ultrasound guidance and either a 14 or 17 gauge radiofrequency needle for twin-reversed arterial perfusion sequence, from 1998 to 2005, was performed by review of hospital and outpatient medical records. Results: The outcomes of all 29 of the patients treated with radiofrequency ablation are known. Twenty-six of the patients had monochorionic-diamniotic pregnancies, whereas 2 had monochorionic-monoamniotic pregnancies. One patient had a triplet pregnancy with a monochorionic-diamniotic pair with TRAP sequence. Overall, 25 of 29 pump twins survived (86%), delivering at a mean gestational age of 34.6 weeks. Survival was 24 of 26 (92%) in monochorionic-diamniotic pregnancies with a mean gestational age of 35.6 weeks. Two women in our early experience sustained thermal injuries from the site of grounding pads. Conclusion: Radiofrequency ablation of the acardiac twin effectively protects the pump twin from high-output cardiac failure and death. Greater than 90% survival can be achieved in monochorionic-diamniotic pregnancies complicated by TRAP sequence with a mean gestation age at time of delivery close to term. Our limited experience in cases of monochorionic-monoamniotic TRAP sequence does not allow the determination of efficacy in this group.
UR - http://www.scopus.com/inward/record.url?scp=34247251891&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34247251891&partnerID=8YFLogxK
U2 - 10.1016/j.ajog.2006.11.039
DO - 10.1016/j.ajog.2006.11.039
M3 - Article
C2 - 17466701
AN - SCOPUS:34247251891
SN - 0002-9378
VL - 196
SP - 459.e1-459.e4
JO - American Journal of Obstetrics and Gynecology
JF - American Journal of Obstetrics and Gynecology
IS - 5
ER -