Fabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate

Ta Jen Li, Chia Yu Lin, A. Balamurugan, Chung Wei Kung, Jen Yuan Wang, Chih Wei Hu, Chun Chieh Wang, Po Yen Chen, R. Vittal, Kuo Chuan Ho

研究成果: Conference article

1 引文 (Scopus)

摘要

A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO 3 -). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is electrodeposited on the GCE by cyclic voltammetric (CV) method. It is noted that FAD can enhance the electrodeposition of PEDOT, and possible reasons are proposed to explain this phenomenon. The optimal cycle number for preparing the modified electrode is determined to be 9. The relationship between the formal potential of FAD and the pH value is studied. Two slopes, 60.4 and 29.2 mV per pH unit, are recorded in the ranges of 1.5 ≦ pH ≦ 8.5 and 8.5 ≦ pH ≦ 11.5, respectively. Additionally, it is found that the oxidation current of iodate increases significantly with the decrease of pH value.

原文English
頁(從 - 到)1453-1456
頁數4
期刊Procedia Engineering
25
DOIs
出版狀態Published - 2011 十二月 1
事件25th Eurosensors Conference - Athens, Greece
持續時間: 2011 九月 42011 九月 7

指紋

Glassy carbon
Fabrication
Electrodes
Composite materials
Polymers
Electrodeposition
Oxidation

All Science Journal Classification (ASJC) codes

  • Engineering(all)

引用此文

Li, Ta Jen ; Lin, Chia Yu ; Balamurugan, A. ; Kung, Chung Wei ; Wang, Jen Yuan ; Hu, Chih Wei ; Wang, Chun Chieh ; Chen, Po Yen ; Vittal, R. ; Ho, Kuo Chuan. / Fabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate. 於: Procedia Engineering. 2011 ; 卷 25. 頁 1453-1456.
@article{27e132da6ed24db8b23cf30875599662,
title = "Fabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate",
abstract = "A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO 3 -). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is electrodeposited on the GCE by cyclic voltammetric (CV) method. It is noted that FAD can enhance the electrodeposition of PEDOT, and possible reasons are proposed to explain this phenomenon. The optimal cycle number for preparing the modified electrode is determined to be 9. The relationship between the formal potential of FAD and the pH value is studied. Two slopes, 60.4 and 29.2 mV per pH unit, are recorded in the ranges of 1.5 ≦ pH ≦ 8.5 and 8.5 ≦ pH ≦ 11.5, respectively. Additionally, it is found that the oxidation current of iodate increases significantly with the decrease of pH value.",
author = "Li, {Ta Jen} and Lin, {Chia Yu} and A. Balamurugan and Kung, {Chung Wei} and Wang, {Jen Yuan} and Hu, {Chih Wei} and Wang, {Chun Chieh} and Chen, {Po Yen} and R. Vittal and Ho, {Kuo Chuan}",
year = "2011",
month = "12",
day = "1",
doi = "10.1016/j.proeng.2011.12.359",
language = "English",
volume = "25",
pages = "1453--1456",
journal = "Procedia Engineering",
issn = "1877-7058",
publisher = "Elsevier BV",

}

Fabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate. / Li, Ta Jen; Lin, Chia Yu; Balamurugan, A.; Kung, Chung Wei; Wang, Jen Yuan; Hu, Chih Wei; Wang, Chun Chieh; Chen, Po Yen; Vittal, R.; Ho, Kuo Chuan.

於: Procedia Engineering, 卷 25, 01.12.2011, p. 1453-1456.

研究成果: Conference article

TY - JOUR

T1 - Fabrication of a polymer/mediator composite modified electrode and its application to electrochemical detection of iodate

AU - Li, Ta Jen

AU - Lin, Chia Yu

AU - Balamurugan, A.

AU - Kung, Chung Wei

AU - Wang, Jen Yuan

AU - Hu, Chih Wei

AU - Wang, Chun Chieh

AU - Chen, Po Yen

AU - Vittal, R.

AU - Ho, Kuo Chuan

PY - 2011/12/1

Y1 - 2011/12/1

N2 - A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO 3 -). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is electrodeposited on the GCE by cyclic voltammetric (CV) method. It is noted that FAD can enhance the electrodeposition of PEDOT, and possible reasons are proposed to explain this phenomenon. The optimal cycle number for preparing the modified electrode is determined to be 9. The relationship between the formal potential of FAD and the pH value is studied. Two slopes, 60.4 and 29.2 mV per pH unit, are recorded in the ranges of 1.5 ≦ pH ≦ 8.5 and 8.5 ≦ pH ≦ 11.5, respectively. Additionally, it is found that the oxidation current of iodate increases significantly with the decrease of pH value.

AB - A polymer/mediator composite modified glassy carbon electrode (GCE) is fabricated for electrochemical detection of iodate (IO 3 -). Flavin adenine dinucleotide (FAD) is chosen as mediator for sensing iodate, and 3,4 ethylenedioxythiophene (EDOT) is chosen for entrapping FAD and forming a conducting polymeric matrix, poly(3,4 ethylenedioxythiophene) (PEDOT). The PEDOT/FAD modification layer is electrodeposited on the GCE by cyclic voltammetric (CV) method. It is noted that FAD can enhance the electrodeposition of PEDOT, and possible reasons are proposed to explain this phenomenon. The optimal cycle number for preparing the modified electrode is determined to be 9. The relationship between the formal potential of FAD and the pH value is studied. Two slopes, 60.4 and 29.2 mV per pH unit, are recorded in the ranges of 1.5 ≦ pH ≦ 8.5 and 8.5 ≦ pH ≦ 11.5, respectively. Additionally, it is found that the oxidation current of iodate increases significantly with the decrease of pH value.

UR - http://www.scopus.com/inward/record.url?scp=84863165112&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84863165112&partnerID=8YFLogxK

U2 - 10.1016/j.proeng.2011.12.359

DO - 10.1016/j.proeng.2011.12.359

M3 - Conference article

AN - SCOPUS:84863165112

VL - 25

SP - 1453

EP - 1456

JO - Procedia Engineering

JF - Procedia Engineering

SN - 1877-7058

ER -