T1 - Implementation of green building specification credits for better thermal conditions in naturally ventilated school buildings
AU - Huang, Kuo Tsang
AU - Huang, Wen Pin
AU - Lin, Tzu Ping
AU - Hwang, Ruey Lung
N1 - Funding Information:
The authors are thankful to the financial support from Ministry of Science and Technology, Taiwan in grant under the Project Number: NSC-102-2221-E-239-028 .
PY - 2015/4/1
Y1 - 2015/4/1
N2 - Most campus buildings in public education in Taiwan are naturally ventilated. Since it is hot and humid in summer, these free-running classrooms are vulnerable to overheating, which may impair the students' learning ability. We studied a Diamond-certified green building campus to determine the effectiveness of the strategies adopted to prevent overheating by quantifying the in-room thermal comfort via long-term in situ monitoring of temperatures. The passive planning and design means used in the case are presented in detail, and the resulting synthesis effect in terms of the relation of indoor thermal comfort to student learning performance is also discussed. The maximum percentage of dissatisfaction in classrooms is 15-22% less than that in the outdoor condition, and the severity of overheating is 12.5%-18.5% of that of the outdoors. The average learning performance is around 1.3% higher than in the outdoor condition. The green building certification system (EEWH) practiced in Taiwan evaluates various aspects regarding thermal comfort enhancement, the studied naturally ventilated school building demonstrates that by complying to these EEWH credits the indoor thermal quality can successfully be ensured.
AB - Most campus buildings in public education in Taiwan are naturally ventilated. Since it is hot and humid in summer, these free-running classrooms are vulnerable to overheating, which may impair the students' learning ability. We studied a Diamond-certified green building campus to determine the effectiveness of the strategies adopted to prevent overheating by quantifying the in-room thermal comfort via long-term in situ monitoring of temperatures. The passive planning and design means used in the case are presented in detail, and the resulting synthesis effect in terms of the relation of indoor thermal comfort to student learning performance is also discussed. The maximum percentage of dissatisfaction in classrooms is 15-22% less than that in the outdoor condition, and the severity of overheating is 12.5%-18.5% of that of the outdoors. The average learning performance is around 1.3% higher than in the outdoor condition. The green building certification system (EEWH) practiced in Taiwan evaluates various aspects regarding thermal comfort enhancement, the studied naturally ventilated school building demonstrates that by complying to these EEWH credits the indoor thermal quality can successfully be ensured.
UR - http://www.scopus.com/inward/record.url?scp=84921528554&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84921528554&partnerID=8YFLogxK
U2 - 10.1016/j.buildenv.2015.01.006
DO - 10.1016/j.buildenv.2015.01.006
M3 - Article
AN - SCOPUS:84921528554
SN - 0360-1323
VL - 86
SP - 141
EP - 150
JO - Building and Environment
JF - Building and Environment
ER -