TY - JOUR
T1 - In vitro and in vivo characterization of SU-8 flexible neuroprobe
T2 - From mechanical properties to electrophysiological recording
AU - Huang, Shun Ho
AU - Lin, Shu Ping
AU - Chen, Jia Jin Jason
N1 - Funding Information:
This work was supported by the National Science Council of Taiwan under grant NSC 101-2221-E-006-006-MY3 and National Health Research Institutes of Taiwan under grant NHRI-EX102-10139EI . Instrumental support for fabricating the SU-8 neuroprobe was given by the Micro-Nano Technology Research Center and the Southern Region Micro-Electro-Mechanical Systems Research Center in Taiwan.
Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2014/9/1
Y1 - 2014/9/1
N2 - Flexible neuroprobe with better tissue compliance exhibits unique mechanical characteristics in maintaining stability of neural implant in vivo. In this study, a flexible neuroprobe using SU-8 was designed and fabricated for in vitro and in vivo electrical sensing to show the improved tissue compatibility compared to that of the traditional rigid neuroprobe. The validation of neuroprobe was achieved by in vitro mechanical and cytotoxicity tests as well as in vivo neural recording and immunohistological staining. The fabrication process consisted of the creation of a backbone structure using photolithography, photopatterning of evaporated metal, and insulating of the electrode trace. The results of mechanical test of our fabricated SU-8 neuroprobe showed four times of physical stress (18.77 mN) than the insertion force (4.69 mN) to sustain resistance from brain tissue during implantation. The in vitro cytotoxicity assay showed well neuronal survival and proved the sufficient surface biocompatibility of the SU-8 neuroprobe. Further in vivo immunohistological staining showed no obvious glia aggregation around the implantation site indicating suitable biocompatibility compared with that of a rigid neuroprobe. Our in vitro and in vivo studies showed SU-8 neuroprobe possessed enough stress to complete the implantation in brain tissue and remained flexibility to comply micromovement of soft tissue with minor immune responses to achieve in vivo electrophysiological recordings at a signal-noise-ratio of greater than 7.
AB - Flexible neuroprobe with better tissue compliance exhibits unique mechanical characteristics in maintaining stability of neural implant in vivo. In this study, a flexible neuroprobe using SU-8 was designed and fabricated for in vitro and in vivo electrical sensing to show the improved tissue compatibility compared to that of the traditional rigid neuroprobe. The validation of neuroprobe was achieved by in vitro mechanical and cytotoxicity tests as well as in vivo neural recording and immunohistological staining. The fabrication process consisted of the creation of a backbone structure using photolithography, photopatterning of evaporated metal, and insulating of the electrode trace. The results of mechanical test of our fabricated SU-8 neuroprobe showed four times of physical stress (18.77 mN) than the insertion force (4.69 mN) to sustain resistance from brain tissue during implantation. The in vitro cytotoxicity assay showed well neuronal survival and proved the sufficient surface biocompatibility of the SU-8 neuroprobe. Further in vivo immunohistological staining showed no obvious glia aggregation around the implantation site indicating suitable biocompatibility compared with that of a rigid neuroprobe. Our in vitro and in vivo studies showed SU-8 neuroprobe possessed enough stress to complete the implantation in brain tissue and remained flexibility to comply micromovement of soft tissue with minor immune responses to achieve in vivo electrophysiological recordings at a signal-noise-ratio of greater than 7.
UR - http://www.scopus.com/inward/record.url?scp=84903608864&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84903608864&partnerID=8YFLogxK
U2 - 10.1016/j.sna.2014.06.005
DO - 10.1016/j.sna.2014.06.005
M3 - Article
AN - SCOPUS:84903608864
SN - 0924-4247
VL - 216
SP - 257
EP - 265
JO - Sensors and Actuators, A: Physical
JF - Sensors and Actuators, A: Physical
ER -