Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies

Le Ren Chang-Chien, Luu Ngoc An, Ta Wei Lin, Wei Jen Lee

研究成果: Article

61 引文 (Scopus)

摘要

Demand response (DR) is considered to be one of the most incentive smart grid functions to enhance power system reliability and control. For the purpose of system security, DR has been utilized to deal with contingent events. In this way, load shedding conducted by the DR program is no longer sorely considered as the last defense line to save system frequency, it should be considered as part of the available fast response resources to cooperate with spinning reserve for balancing generation and demand under some specific conditions. This paper proposes an overall frequency restoration plan considering the DR and spinning reserve. The frequency restoration is designed using the DR as the first option to intercept frequency decline for a large disturbance, followed by the scheduled spinning reserve to raise frequency back to the pre-disturbance level. The proposed scheme is especially developed to intelligently deploy DR for coordinating with different spinning reserve constraints and contingency scenarios. Tests of the proposed frequency restoration scheme are evaluated by simulation where the system data was retrieved from frequency events in a utility. Test results show that the proposed spinning reserve and DR deployment could effectively restore frequency under various contingency scenarios.

原文English
文章編號6213578
頁(從 - 到)1145-1153
頁數9
期刊IEEE Transactions on Smart Grid
3
發行號3
DOIs
出版狀態Published - 2012 六月 14

指紋

Restoration
Security systems

All Science Journal Classification (ASJC) codes

  • Computer Science(all)

引用此文

@article{81ebc78310c2457f8ef9cae3018a3f73,
title = "Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies",
abstract = "Demand response (DR) is considered to be one of the most incentive smart grid functions to enhance power system reliability and control. For the purpose of system security, DR has been utilized to deal with contingent events. In this way, load shedding conducted by the DR program is no longer sorely considered as the last defense line to save system frequency, it should be considered as part of the available fast response resources to cooperate with spinning reserve for balancing generation and demand under some specific conditions. This paper proposes an overall frequency restoration plan considering the DR and spinning reserve. The frequency restoration is designed using the DR as the first option to intercept frequency decline for a large disturbance, followed by the scheduled spinning reserve to raise frequency back to the pre-disturbance level. The proposed scheme is especially developed to intelligently deploy DR for coordinating with different spinning reserve constraints and contingency scenarios. Tests of the proposed frequency restoration scheme are evaluated by simulation where the system data was retrieved from frequency events in a utility. Test results show that the proposed spinning reserve and DR deployment could effectively restore frequency under various contingency scenarios.",
author = "Chang-Chien, {Le Ren} and An, {Luu Ngoc} and Lin, {Ta Wei} and Lee, {Wei Jen}",
year = "2012",
month = "6",
day = "14",
doi = "10.1109/TSG.2012.2192297",
language = "English",
volume = "3",
pages = "1145--1153",
journal = "IEEE Transactions on Smart Grid",
issn = "1949-3053",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "3",

}

Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies. / Chang-Chien, Le Ren; An, Luu Ngoc; Lin, Ta Wei; Lee, Wei Jen.

於: IEEE Transactions on Smart Grid, 卷 3, 編號 3, 6213578, 14.06.2012, p. 1145-1153.

研究成果: Article

TY - JOUR

T1 - Incorporating demand response with spinning reserve to realize an adaptive frequency restoration plan for system contingencies

AU - Chang-Chien, Le Ren

AU - An, Luu Ngoc

AU - Lin, Ta Wei

AU - Lee, Wei Jen

PY - 2012/6/14

Y1 - 2012/6/14

N2 - Demand response (DR) is considered to be one of the most incentive smart grid functions to enhance power system reliability and control. For the purpose of system security, DR has been utilized to deal with contingent events. In this way, load shedding conducted by the DR program is no longer sorely considered as the last defense line to save system frequency, it should be considered as part of the available fast response resources to cooperate with spinning reserve for balancing generation and demand under some specific conditions. This paper proposes an overall frequency restoration plan considering the DR and spinning reserve. The frequency restoration is designed using the DR as the first option to intercept frequency decline for a large disturbance, followed by the scheduled spinning reserve to raise frequency back to the pre-disturbance level. The proposed scheme is especially developed to intelligently deploy DR for coordinating with different spinning reserve constraints and contingency scenarios. Tests of the proposed frequency restoration scheme are evaluated by simulation where the system data was retrieved from frequency events in a utility. Test results show that the proposed spinning reserve and DR deployment could effectively restore frequency under various contingency scenarios.

AB - Demand response (DR) is considered to be one of the most incentive smart grid functions to enhance power system reliability and control. For the purpose of system security, DR has been utilized to deal with contingent events. In this way, load shedding conducted by the DR program is no longer sorely considered as the last defense line to save system frequency, it should be considered as part of the available fast response resources to cooperate with spinning reserve for balancing generation and demand under some specific conditions. This paper proposes an overall frequency restoration plan considering the DR and spinning reserve. The frequency restoration is designed using the DR as the first option to intercept frequency decline for a large disturbance, followed by the scheduled spinning reserve to raise frequency back to the pre-disturbance level. The proposed scheme is especially developed to intelligently deploy DR for coordinating with different spinning reserve constraints and contingency scenarios. Tests of the proposed frequency restoration scheme are evaluated by simulation where the system data was retrieved from frequency events in a utility. Test results show that the proposed spinning reserve and DR deployment could effectively restore frequency under various contingency scenarios.

UR - http://www.scopus.com/inward/record.url?scp=84865455550&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84865455550&partnerID=8YFLogxK

U2 - 10.1109/TSG.2012.2192297

DO - 10.1109/TSG.2012.2192297

M3 - Article

AN - SCOPUS:84865455550

VL - 3

SP - 1145

EP - 1153

JO - IEEE Transactions on Smart Grid

JF - IEEE Transactions on Smart Grid

SN - 1949-3053

IS - 3

M1 - 6213578

ER -