Linear control of electrochemical tubular reactor system-Removal of Cr(VI) from wastewaters

Wei Wu, Jiyan Jh Peng

研究成果: Article同行評審

6 引文 斯高帕斯(Scopus)

摘要

An electrochemical tubular reactor system, which is used to remove the hexavalent chromium Cr(VI) from wastewaters, is presented. Under specific modeling and operating constraints, the axial dispersion reactor is described by the coupled nonlinear partial differential equations (PDEs) under Danckwerts boundary conditions. Through the composite finite difference combination, the lumped differential-algebraic equations (DAEs) turn out to be a two-input/two-output system. The overall system stability analysis is investigated via the Lyapunov's first method. According to the prescribed control configuration, the closed-loop simulation shows that a multi-loop PID control scheme can ensure the outlet concentration of Cr(VI) less than 0.5. mg/L in wastewaters.

原文English
頁(從 - 到)498-505
頁數8
期刊Journal of the Taiwan Institute of Chemical Engineers
42
發行號3
DOIs
出版狀態Published - 2011 五月

All Science Journal Classification (ASJC) codes

  • Chemistry(all)
  • Chemical Engineering(all)

指紋 深入研究「Linear control of electrochemical tubular reactor system-Removal of Cr(VI) from wastewaters」主題。共同形成了獨特的指紋。