摘要
Purpose: This study aimed to validate standard deviations of lung densities obtained using high-pitch dual-source computed tomography (DSCT) densitometry as indices of bronchopulmonary dysplasia (BPD) severity in premature infants. Methods: Data of preterm, late preterm group, and early term groups were evaluated. Mean and median standard deviations (SDmean, SDmedian) of CT lung density (CTLD) were calculated from CT images. Results: SDmean of CTLD in infants with severe BPD was significantly higher than that of infants without BPD (198.1 vs. 140.9, respectively; P. =. .002). Conclusions: Study results support using high-pitch DSCT for BPD diagnosis and quantitative evaluation in prematurity.
| 原文 | English |
|---|---|
| 頁(從 - 到) | 594-600 |
| 頁數 | 7 |
| 期刊 | Clinical Imaging |
| 卷 | 40 |
| 發行號 | 4 |
| DOIs | |
| 出版狀態 | Published - 2016 7月 1 |
All Science Journal Classification (ASJC) codes
- 放射學、核子醫學和影像學
指紋
深入研究「Lung density standard deviations obtained using high-pitch dual-source computed tomography are valid predictors of bronchopulmonary dysplasia in preterm infants」主題。共同形成了獨特的指紋。引用此