TY - JOUR
T1 - Mid-range shoulder instability modeled as a cam-follower mechanism
AU - Willemot, Laurent
AU - Thoreson, Andrew
AU - Ryan Breighner, Breighner
AU - Hooke, Alexander
AU - Verborgt, Olivier
AU - An, Kai Nan
N1 - Funding Information:
This research was partly funded by the Belgian Society for Orthopeadics and Traumatology (BVOT, Belgische Vereniging voor Orthopedie en Traumatologie), and partly by the More Foundation of AZ Monica, Deurne, Belgium .
Publisher Copyright:
© 2015 Elsevier Ltd.
Copyright:
Copyright 2016 Elsevier B.V., All rights reserved.
PY - 2015/7/16
Y1 - 2015/7/16
N2 - In this paper, we model a simplified glenohumeral joint as a cam-follower mechanism during experimental simulated dislocation. Thus, humeral head trajectory and translational forces are predicted using only contact surface geometry and compressive forces as function inputs. We demonstrate this new interpretation of glenohumeral stability and verify the accuracy of the method by physically testing a custom-molded, idealized shoulder model and comparing data to the output of the 2D mathematical model. Comparison of translational forces between experimental and mathematical approaches resulted in r2 of 0.88 and 0.90 for the small and large humeral head sizes, respectively. Comparison of the lateral displacement resulted in r2 of 0.99 and 0.98 for the small and larger humeral head sizes, respectively. Comparing translational forces between experiments and the mathematical model when varying the compressive force to 30N, 60N, and 90N resulted in r2 of 0.90, 0.82, and 0.89, respectively. The preliminary success of this study is motivation to introduce the effects of soft tissue such as cartilage and validation with a cadaver model. The use of simple mathematical models such as this aid in the set-up and understanding of experiments in stability research and avoid unnecessary depletion of cadaveric resources.
AB - In this paper, we model a simplified glenohumeral joint as a cam-follower mechanism during experimental simulated dislocation. Thus, humeral head trajectory and translational forces are predicted using only contact surface geometry and compressive forces as function inputs. We demonstrate this new interpretation of glenohumeral stability and verify the accuracy of the method by physically testing a custom-molded, idealized shoulder model and comparing data to the output of the 2D mathematical model. Comparison of translational forces between experimental and mathematical approaches resulted in r2 of 0.88 and 0.90 for the small and large humeral head sizes, respectively. Comparison of the lateral displacement resulted in r2 of 0.99 and 0.98 for the small and larger humeral head sizes, respectively. Comparing translational forces between experiments and the mathematical model when varying the compressive force to 30N, 60N, and 90N resulted in r2 of 0.90, 0.82, and 0.89, respectively. The preliminary success of this study is motivation to introduce the effects of soft tissue such as cartilage and validation with a cadaver model. The use of simple mathematical models such as this aid in the set-up and understanding of experiments in stability research and avoid unnecessary depletion of cadaveric resources.
UR - http://www.scopus.com/inward/record.url?scp=84937521688&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84937521688&partnerID=8YFLogxK
U2 - 10.1016/j.jbiomech.2015.02.053
DO - 10.1016/j.jbiomech.2015.02.053
M3 - Article
C2 - 25865644
AN - SCOPUS:84937521688
SN - 0021-9290
VL - 48
SP - 2227
EP - 2231
JO - Journal of Biomechanics
JF - Journal of Biomechanics
IS - 10
ER -