TY - JOUR
T1 - Novel sliding hybrid microchip detection system for determination of whole blood phosphorus concentration
AU - Tseng, Chin Chung
AU - Chen, Szu Jui
AU - Lu, Song Yu
AU - Ko, Chien Hsuan
AU - Wang, Ju Ming
AU - Fu, Lung Ming
AU - Liu, Yu Hsien
N1 - Funding Information:
The authors would like to thank the Ministry of Science and Technology of Taiwan for the financial support of this study under Grant Nos. MOST 106-2314-B-006-085-MY3 , MOST 109-2622-E-006-009-CC , and MOST 109-2221-E-006 -043 -MY3 .
Publisher Copyright:
© 2021 Elsevier B.V.
PY - 2021/9/1
Y1 - 2021/9/1
N2 - A novel detection system consisting of a three-dimensional (3-D) sliding hybrid microchip (SHM) and a smart analysis device is presented to determine the phosphorus concentration in whole blood samples. The novelty of the SHM detection system includes filtering whole blood directly into serum, reacting different reagents in stages, performing a closed-type reaction to prevent evaporation of the test sample and uniform heating. The SHM is fabricated on PET and PMMA substrates and incorporates a sample injection zone, a filter paper-strip, two paper-chip reagent zones (reagent A and reagent B), and a detection zone. In the proposed detection method, 6 μL of whole blood sample is injected into the sample chamber and is filtered / separated by the paper-strip as it diffuses toward reagent zone A under the effects of capillary action. After 1 min, the sliding mechanism of the SHM is activated such that reagent zone B is positioned over reagent zone A in the detection/reaction zone. The SHM is then inserted into the smart analysis device and heated at 35°C for 4 min to prompt a modified molybdenum blue reaction. Finally, the blood phosphorus concentration is measured through a colorimetric method performed by a self-developed color analysis app installed on a smartphone. The feasibility of the current SHM detection system is demonstrated by the known control serum phosphorus concentrations ranging from 0.1–9 mg/dL. It is shown that the total R + B + G color intensity of the reaction complex image (Y) is linearly related to the serum phosphorus concentration (X) as Y = -31.502X + 600.740. The coefficient of determination (R2) and detection limit are 0.9936 and 0.06 mg/dL, respectively. The phosphorus concentration detection results obtained using the current SHM system for the whole blood samples of 100 real-world chronic kidney disease (CKD) patients are shown to be in excellent consistent with the detection results acquired through a macroscopic technique. Overall, the current SHM detection system provides a rapid and reliable method to detect the phosphorus concentration in whole blood samples.
AB - A novel detection system consisting of a three-dimensional (3-D) sliding hybrid microchip (SHM) and a smart analysis device is presented to determine the phosphorus concentration in whole blood samples. The novelty of the SHM detection system includes filtering whole blood directly into serum, reacting different reagents in stages, performing a closed-type reaction to prevent evaporation of the test sample and uniform heating. The SHM is fabricated on PET and PMMA substrates and incorporates a sample injection zone, a filter paper-strip, two paper-chip reagent zones (reagent A and reagent B), and a detection zone. In the proposed detection method, 6 μL of whole blood sample is injected into the sample chamber and is filtered / separated by the paper-strip as it diffuses toward reagent zone A under the effects of capillary action. After 1 min, the sliding mechanism of the SHM is activated such that reagent zone B is positioned over reagent zone A in the detection/reaction zone. The SHM is then inserted into the smart analysis device and heated at 35°C for 4 min to prompt a modified molybdenum blue reaction. Finally, the blood phosphorus concentration is measured through a colorimetric method performed by a self-developed color analysis app installed on a smartphone. The feasibility of the current SHM detection system is demonstrated by the known control serum phosphorus concentrations ranging from 0.1–9 mg/dL. It is shown that the total R + B + G color intensity of the reaction complex image (Y) is linearly related to the serum phosphorus concentration (X) as Y = -31.502X + 600.740. The coefficient of determination (R2) and detection limit are 0.9936 and 0.06 mg/dL, respectively. The phosphorus concentration detection results obtained using the current SHM system for the whole blood samples of 100 real-world chronic kidney disease (CKD) patients are shown to be in excellent consistent with the detection results acquired through a macroscopic technique. Overall, the current SHM detection system provides a rapid and reliable method to detect the phosphorus concentration in whole blood samples.
UR - http://www.scopus.com/inward/record.url?scp=85104063105&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85104063105&partnerID=8YFLogxK
U2 - 10.1016/j.cej.2021.129592
DO - 10.1016/j.cej.2021.129592
M3 - Article
AN - SCOPUS:85104063105
SN - 1385-8947
VL - 419
JO - Chemical Engineering Journal
JF - Chemical Engineering Journal
M1 - 129592
ER -