Optimum propulsion technique in different wheelchair handrim diameter

Lan Yuen Guo, Fong-chin Su, Kai Nan An

研究成果: Article

2 引文 (Scopus)

摘要

Variability in the propulsion technique to manual wheelchair users due to differences in level of injury and wheelchair fit makes detection of subtle changes in technique due to manipulation of individual variables nearly impossible. However, such changes are well suited to analytical modeling techniques, since variables can be manipulated systematically and the effects of the manipulation can be easily quantified. Therefore, we develop a simple two-dimensional model of the upper arm, forearm, and wheelchair wheel to study changes in wheelchair-user interface. Variations in handrim diameter were examined for their influence in the propulsive moment generated by each subject. The larger the handrim, the greater the moment about the wheel axle Mr could attain. The tangential force Ft applied to the handrim was similar among three handrim diameters. However, the radial component of force applied to the handrim increased as handrim diameter decreased. Increasing rim diameter increased the fraction effective force. Both predicted Mr and Ft reached the peak value in the terminal propulsion phase, in agreement with experimental results of the quasi-static wheelchair propulsion, but not dynamic, cyclic wheelchair propulsion. During the middle to terminal propulsion phase, the optimized force vector is not tangential to the handrim and instead, it pass through the upper arm segment which is comparable to dynamic wheelchair propulsion. Optimum analysis could help us to identify the effect of handrim diameter and investigate the related characteristics. Also, through modeling, the mechanical constraints of force application and the inadequate of pushing technique are further understood.

原文English
頁(從 - 到)1-10
頁數10
期刊Journal of Medical and Biological Engineering
22
發行號1
出版狀態Published - 2002 一月 1

指紋

Wheelchairs
Propulsion
Wheels
Arm
Axles
Forearm
User interfaces
Wounds and Injuries

All Science Journal Classification (ASJC) codes

  • Biomedical Engineering

引用此文

@article{75a3614d3d1b4751a317d3aa9108f38c,
title = "Optimum propulsion technique in different wheelchair handrim diameter",
abstract = "Variability in the propulsion technique to manual wheelchair users due to differences in level of injury and wheelchair fit makes detection of subtle changes in technique due to manipulation of individual variables nearly impossible. However, such changes are well suited to analytical modeling techniques, since variables can be manipulated systematically and the effects of the manipulation can be easily quantified. Therefore, we develop a simple two-dimensional model of the upper arm, forearm, and wheelchair wheel to study changes in wheelchair-user interface. Variations in handrim diameter were examined for their influence in the propulsive moment generated by each subject. The larger the handrim, the greater the moment about the wheel axle Mr could attain. The tangential force Ft applied to the handrim was similar among three handrim diameters. However, the radial component of force applied to the handrim increased as handrim diameter decreased. Increasing rim diameter increased the fraction effective force. Both predicted Mr and Ft reached the peak value in the terminal propulsion phase, in agreement with experimental results of the quasi-static wheelchair propulsion, but not dynamic, cyclic wheelchair propulsion. During the middle to terminal propulsion phase, the optimized force vector is not tangential to the handrim and instead, it pass through the upper arm segment which is comparable to dynamic wheelchair propulsion. Optimum analysis could help us to identify the effect of handrim diameter and investigate the related characteristics. Also, through modeling, the mechanical constraints of force application and the inadequate of pushing technique are further understood.",
author = "Guo, {Lan Yuen} and Fong-chin Su and An, {Kai Nan}",
year = "2002",
month = "1",
day = "1",
language = "English",
volume = "22",
pages = "1--10",
journal = "Journal of Medical and Biological Engineering",
issn = "1609-0985",
publisher = "Biomedical Engineering Society",
number = "1",

}

Optimum propulsion technique in different wheelchair handrim diameter. / Guo, Lan Yuen; Su, Fong-chin; An, Kai Nan.

於: Journal of Medical and Biological Engineering, 卷 22, 編號 1, 01.01.2002, p. 1-10.

研究成果: Article

TY - JOUR

T1 - Optimum propulsion technique in different wheelchair handrim diameter

AU - Guo, Lan Yuen

AU - Su, Fong-chin

AU - An, Kai Nan

PY - 2002/1/1

Y1 - 2002/1/1

N2 - Variability in the propulsion technique to manual wheelchair users due to differences in level of injury and wheelchair fit makes detection of subtle changes in technique due to manipulation of individual variables nearly impossible. However, such changes are well suited to analytical modeling techniques, since variables can be manipulated systematically and the effects of the manipulation can be easily quantified. Therefore, we develop a simple two-dimensional model of the upper arm, forearm, and wheelchair wheel to study changes in wheelchair-user interface. Variations in handrim diameter were examined for their influence in the propulsive moment generated by each subject. The larger the handrim, the greater the moment about the wheel axle Mr could attain. The tangential force Ft applied to the handrim was similar among three handrim diameters. However, the radial component of force applied to the handrim increased as handrim diameter decreased. Increasing rim diameter increased the fraction effective force. Both predicted Mr and Ft reached the peak value in the terminal propulsion phase, in agreement with experimental results of the quasi-static wheelchair propulsion, but not dynamic, cyclic wheelchair propulsion. During the middle to terminal propulsion phase, the optimized force vector is not tangential to the handrim and instead, it pass through the upper arm segment which is comparable to dynamic wheelchair propulsion. Optimum analysis could help us to identify the effect of handrim diameter and investigate the related characteristics. Also, through modeling, the mechanical constraints of force application and the inadequate of pushing technique are further understood.

AB - Variability in the propulsion technique to manual wheelchair users due to differences in level of injury and wheelchair fit makes detection of subtle changes in technique due to manipulation of individual variables nearly impossible. However, such changes are well suited to analytical modeling techniques, since variables can be manipulated systematically and the effects of the manipulation can be easily quantified. Therefore, we develop a simple two-dimensional model of the upper arm, forearm, and wheelchair wheel to study changes in wheelchair-user interface. Variations in handrim diameter were examined for their influence in the propulsive moment generated by each subject. The larger the handrim, the greater the moment about the wheel axle Mr could attain. The tangential force Ft applied to the handrim was similar among three handrim diameters. However, the radial component of force applied to the handrim increased as handrim diameter decreased. Increasing rim diameter increased the fraction effective force. Both predicted Mr and Ft reached the peak value in the terminal propulsion phase, in agreement with experimental results of the quasi-static wheelchair propulsion, but not dynamic, cyclic wheelchair propulsion. During the middle to terminal propulsion phase, the optimized force vector is not tangential to the handrim and instead, it pass through the upper arm segment which is comparable to dynamic wheelchair propulsion. Optimum analysis could help us to identify the effect of handrim diameter and investigate the related characteristics. Also, through modeling, the mechanical constraints of force application and the inadequate of pushing technique are further understood.

UR - http://www.scopus.com/inward/record.url?scp=0036244338&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036244338&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0036244338

VL - 22

SP - 1

EP - 10

JO - Journal of Medical and Biological Engineering

JF - Journal of Medical and Biological Engineering

SN - 1609-0985

IS - 1

ER -