TY - JOUR
T1 - Rapid tear screening of diabetic retinopathy by a detachable surface acoustic wave enabled immunosensor
AU - Das, Dhrubajyoti
AU - Chen, Hsuan An
AU - Weng, Chao Li
AU - Lee, Yung Chun
AU - Hsu, Sheng Min
AU - Kwon, Jae Sung
AU - Chuang, Han Sheng
N1 - Publisher Copyright:
© 2024 Elsevier B.V.
PY - 2024/10/9
Y1 - 2024/10/9
N2 - Background: Diabetic retinopathy (DR), a chronic and progressive microvascular complication of diabetes mellitus, substantially threatens vision and is a leading cause of blindness among working-age individuals worldwide. Traditional diagnostic methods, such as ophthalmoscopy and fluorescein angiography are nonquantitative, invasive, and time consuming. Analysis of protein biomarkers in tear fluid offers noninvasive insights into ocular and systemic health, aiding in early DR detection. This study introduces a surface acoustic wave (SAW) microchip that rapidly enhances fluorescence in bead-based immunoassays for the sensitive and noninvasive DR detection from human tear samples. Results: The device facilitated particle mixing for immunoassay formation and particle concentration in the droplet, resulting in an enhanced immunofluorescence signal. This detachable SAW microchip allows the disposal of the cover glass after every use, thereby improving the reusability of the interdigital transducer and minimizing potential cross-contamination. A preliminary clinical test was conducted on a cohort of 10 volunteers, including DR patients and healthy individuals. The results demonstrated strong agreement with ELISA studies, validating the high accuracy rate of the SAW microchip. Significance: This comprehensive study offers significant insights into the potential application of a novel SAW microchip for the early detection of DR in individuals with diabetes. By utilizing protein biomarkers found in tear fluid, the device facilitates noninvasive, rapid, and sensitive detection, potentially revolutionizing DR diagnostics and improving patient outcomes through timely intervention and management of this vision-threatening condition.
AB - Background: Diabetic retinopathy (DR), a chronic and progressive microvascular complication of diabetes mellitus, substantially threatens vision and is a leading cause of blindness among working-age individuals worldwide. Traditional diagnostic methods, such as ophthalmoscopy and fluorescein angiography are nonquantitative, invasive, and time consuming. Analysis of protein biomarkers in tear fluid offers noninvasive insights into ocular and systemic health, aiding in early DR detection. This study introduces a surface acoustic wave (SAW) microchip that rapidly enhances fluorescence in bead-based immunoassays for the sensitive and noninvasive DR detection from human tear samples. Results: The device facilitated particle mixing for immunoassay formation and particle concentration in the droplet, resulting in an enhanced immunofluorescence signal. This detachable SAW microchip allows the disposal of the cover glass after every use, thereby improving the reusability of the interdigital transducer and minimizing potential cross-contamination. A preliminary clinical test was conducted on a cohort of 10 volunteers, including DR patients and healthy individuals. The results demonstrated strong agreement with ELISA studies, validating the high accuracy rate of the SAW microchip. Significance: This comprehensive study offers significant insights into the potential application of a novel SAW microchip for the early detection of DR in individuals with diabetes. By utilizing protein biomarkers found in tear fluid, the device facilitates noninvasive, rapid, and sensitive detection, potentially revolutionizing DR diagnostics and improving patient outcomes through timely intervention and management of this vision-threatening condition.
UR - http://www.scopus.com/inward/record.url?scp=85201370077&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85201370077&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2024.343117
DO - 10.1016/j.aca.2024.343117
M3 - Article
C2 - 39244304
AN - SCOPUS:85201370077
SN - 0003-2670
VL - 1325
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
M1 - 343117
ER -