Review of the PWM Control Circuits for Power Converters

Wen Wei Chen, Jiann-Fuh Chen

研究成果: Chapter

摘要

Two types of the conventional fixed-frequency pulse width modulated control circuits based on connection form are typically used, namely, voltage-mode control circuit and current-mode control circuit. For power converters of integrated circuit, it is commonly used with the current-mode control circuit instead of the voltage-mode control circuit, because the current-mode control circuit has a voltage feedback loop in addition to a current feedback loop, so it has faster transient response than the voltage-mode control circuit. This chapter will be compared between voltage-mode control circuit and current-mode control circuit.A well compensation design is the most important to increase the load transient response for switching converters of integrated circuit, so the different types of compensation design will also be given in this chapter.

原文English
主出版物標題Power Systems
發行者Springer Verlag
頁面37-79
頁數43
版本9789811070037
DOIs
出版狀態Published - 2018 一月 1

出版系列

名字Power Systems
號碼9789811070037
ISSN(列印)1612-1287
ISSN(電子)1860-4676

指紋

Power converters
Pulse width modulation
Networks (circuits)
Electric potential
Transient analysis
Integrated circuits
Feedback

All Science Journal Classification (ASJC) codes

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

引用此文

Chen, W. W., & Chen, J-F. (2018). Review of the PWM Control Circuits for Power Converters. 於 Power Systems (9789811070037 編輯, 頁 37-79). (Power Systems; 編號 9789811070037). Springer Verlag. https://doi.org/10.1007/978-981-10-7004-4_2
Chen, Wen Wei ; Chen, Jiann-Fuh. / Review of the PWM Control Circuits for Power Converters. Power Systems. 9789811070037. 編輯 Springer Verlag, 2018. 頁 37-79 (Power Systems; 9789811070037).
@inbook{52089e2a557248f68bb3f5864cfaed5a,
title = "Review of the PWM Control Circuits for Power Converters",
abstract = "Two types of the conventional fixed-frequency pulse width modulated control circuits based on connection form are typically used, namely, voltage-mode control circuit and current-mode control circuit. For power converters of integrated circuit, it is commonly used with the current-mode control circuit instead of the voltage-mode control circuit, because the current-mode control circuit has a voltage feedback loop in addition to a current feedback loop, so it has faster transient response than the voltage-mode control circuit. This chapter will be compared between voltage-mode control circuit and current-mode control circuit.A well compensation design is the most important to increase the load transient response for switching converters of integrated circuit, so the different types of compensation design will also be given in this chapter.",
author = "Chen, {Wen Wei} and Jiann-Fuh Chen",
year = "2018",
month = "1",
day = "1",
doi = "10.1007/978-981-10-7004-4_2",
language = "English",
series = "Power Systems",
publisher = "Springer Verlag",
number = "9789811070037",
pages = "37--79",
booktitle = "Power Systems",
address = "Germany",
edition = "9789811070037",

}

Chen, WW & Chen, J-F 2018, Review of the PWM Control Circuits for Power Converters. 於 Power Systems. 9789811070037 edn, Power Systems, 編號 9789811070037, Springer Verlag, 頁 37-79. https://doi.org/10.1007/978-981-10-7004-4_2

Review of the PWM Control Circuits for Power Converters. / Chen, Wen Wei; Chen, Jiann-Fuh.

Power Systems. 9789811070037. 編輯 Springer Verlag, 2018. p. 37-79 (Power Systems; 編號 9789811070037).

研究成果: Chapter

TY - CHAP

T1 - Review of the PWM Control Circuits for Power Converters

AU - Chen, Wen Wei

AU - Chen, Jiann-Fuh

PY - 2018/1/1

Y1 - 2018/1/1

N2 - Two types of the conventional fixed-frequency pulse width modulated control circuits based on connection form are typically used, namely, voltage-mode control circuit and current-mode control circuit. For power converters of integrated circuit, it is commonly used with the current-mode control circuit instead of the voltage-mode control circuit, because the current-mode control circuit has a voltage feedback loop in addition to a current feedback loop, so it has faster transient response than the voltage-mode control circuit. This chapter will be compared between voltage-mode control circuit and current-mode control circuit.A well compensation design is the most important to increase the load transient response for switching converters of integrated circuit, so the different types of compensation design will also be given in this chapter.

AB - Two types of the conventional fixed-frequency pulse width modulated control circuits based on connection form are typically used, namely, voltage-mode control circuit and current-mode control circuit. For power converters of integrated circuit, it is commonly used with the current-mode control circuit instead of the voltage-mode control circuit, because the current-mode control circuit has a voltage feedback loop in addition to a current feedback loop, so it has faster transient response than the voltage-mode control circuit. This chapter will be compared between voltage-mode control circuit and current-mode control circuit.A well compensation design is the most important to increase the load transient response for switching converters of integrated circuit, so the different types of compensation design will also be given in this chapter.

UR - http://www.scopus.com/inward/record.url?scp=85039984583&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85039984583&partnerID=8YFLogxK

U2 - 10.1007/978-981-10-7004-4_2

DO - 10.1007/978-981-10-7004-4_2

M3 - Chapter

AN - SCOPUS:85039984583

T3 - Power Systems

SP - 37

EP - 79

BT - Power Systems

PB - Springer Verlag

ER -

Chen WW, Chen J-F. Review of the PWM Control Circuits for Power Converters. 於 Power Systems. 9789811070037 編輯 Springer Verlag. 2018. p. 37-79. (Power Systems; 9789811070037). https://doi.org/10.1007/978-981-10-7004-4_2