Salvage Eustachian Tube Cartilage Chip Insertion After Multiple Transnasal Shim Operations in Intractable Patulous Eustachian Tube

研究成果: Article同行評審

摘要

This article presents 2 cases of extremely intractable patulous Eustachian tube following multiple transnasal shim insertion. These cases highlight the disadvantages of repeat transnasal shim operations, including enlargement of the Eustachian tube lumen, frequent dislocation, repeat surgery, recurrent middle ear infection, and shim misswallowing. The patients in these cases were successfully treated with Eustachian tube cartilage chip insertion through a postauricular approach. We describe the surgical technique and advantages of this promising management method.

原文English
頁(從 - 到)NP119-NP122
期刊Ear, Nose and Throat Journal
102
發行號3
DOIs
出版狀態Published - 2023 3月