Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system

Anirban Sinha, Priya Gopinathan, Yi Da Chung, Shu-Chu Shiesh, Gwo Bin Lee

研究成果: Article

摘要

Although cardiovascular diseases such as heart failure (HF) affect 30 million people globally, the early detection of HF has, until recently, been difficult and prone to misdiagnoses. Monitoring the circulatory levels of a relatively new biomarker, the N-terminal prohormone of a B-type natriuretic peptide, could be used for early risk evaluation of HF. Therefore, we developed a pneumatically-driven, automatic integrated microfluidic platform equipped with micromixers, micropumps, and microvalves for the simultaneous detection of NT-proBNP in up to six clinical samples within 25 min by using a novel aptamer-based sandwich assay, and the limit of detection was only 1.53 pg mL-1; given that the chip is 64% more compact than those developed in our prior works and requires only 5 μL of sample input, it may serve as a promising tool for early diagnosis of HF.

原文English
頁(從 - 到)1676-1685
頁數10
期刊Lab on a Chip
19
發行號9
DOIs
出版狀態Published - 2019 一月 1

指紋

Microfluidics
Assays
Heart Failure
Brain Natriuretic Peptide
Biomarkers
Diagnostic Errors
Limit of Detection
Early Diagnosis
Cardiovascular Diseases
pro-brain natriuretic peptide (1-76)
Monitoring

All Science Journal Classification (ASJC) codes

  • Bioengineering
  • Biochemistry
  • Chemistry(all)
  • Biomedical Engineering

引用此文

Sinha, Anirban ; Gopinathan, Priya ; Chung, Yi Da ; Shiesh, Shu-Chu ; Lee, Gwo Bin. / Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system. 於: Lab on a Chip. 2019 ; 卷 19, 編號 9. 頁 1676-1685.
@article{f8597b74a0a94e2f999705cbbbf761a6,
title = "Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system",
abstract = "Although cardiovascular diseases such as heart failure (HF) affect 30 million people globally, the early detection of HF has, until recently, been difficult and prone to misdiagnoses. Monitoring the circulatory levels of a relatively new biomarker, the N-terminal prohormone of a B-type natriuretic peptide, could be used for early risk evaluation of HF. Therefore, we developed a pneumatically-driven, automatic integrated microfluidic platform equipped with micromixers, micropumps, and microvalves for the simultaneous detection of NT-proBNP in up to six clinical samples within 25 min by using a novel aptamer-based sandwich assay, and the limit of detection was only 1.53 pg mL-1; given that the chip is 64{\%} more compact than those developed in our prior works and requires only 5 μL of sample input, it may serve as a promising tool for early diagnosis of HF.",
author = "Anirban Sinha and Priya Gopinathan and Chung, {Yi Da} and Shu-Chu Shiesh and Lee, {Gwo Bin}",
year = "2019",
month = "1",
day = "1",
doi = "10.1039/c9lc00115h",
language = "English",
volume = "19",
pages = "1676--1685",
journal = "Lab on a Chip - Miniaturisation for Chemistry and Biology",
issn = "1473-0197",
publisher = "Royal Society of Chemistry",
number = "9",

}

Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system. / Sinha, Anirban; Gopinathan, Priya; Chung, Yi Da; Shiesh, Shu-Chu; Lee, Gwo Bin.

於: Lab on a Chip, 卷 19, 編號 9, 01.01.2019, p. 1676-1685.

研究成果: Article

TY - JOUR

T1 - Simultaneous detection of multiple NT-proBNP clinical samples utilizing an aptamer-based sandwich assay on an integrated microfluidic system

AU - Sinha, Anirban

AU - Gopinathan, Priya

AU - Chung, Yi Da

AU - Shiesh, Shu-Chu

AU - Lee, Gwo Bin

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Although cardiovascular diseases such as heart failure (HF) affect 30 million people globally, the early detection of HF has, until recently, been difficult and prone to misdiagnoses. Monitoring the circulatory levels of a relatively new biomarker, the N-terminal prohormone of a B-type natriuretic peptide, could be used for early risk evaluation of HF. Therefore, we developed a pneumatically-driven, automatic integrated microfluidic platform equipped with micromixers, micropumps, and microvalves for the simultaneous detection of NT-proBNP in up to six clinical samples within 25 min by using a novel aptamer-based sandwich assay, and the limit of detection was only 1.53 pg mL-1; given that the chip is 64% more compact than those developed in our prior works and requires only 5 μL of sample input, it may serve as a promising tool for early diagnosis of HF.

AB - Although cardiovascular diseases such as heart failure (HF) affect 30 million people globally, the early detection of HF has, until recently, been difficult and prone to misdiagnoses. Monitoring the circulatory levels of a relatively new biomarker, the N-terminal prohormone of a B-type natriuretic peptide, could be used for early risk evaluation of HF. Therefore, we developed a pneumatically-driven, automatic integrated microfluidic platform equipped with micromixers, micropumps, and microvalves for the simultaneous detection of NT-proBNP in up to six clinical samples within 25 min by using a novel aptamer-based sandwich assay, and the limit of detection was only 1.53 pg mL-1; given that the chip is 64% more compact than those developed in our prior works and requires only 5 μL of sample input, it may serve as a promising tool for early diagnosis of HF.

UR - http://www.scopus.com/inward/record.url?scp=85064978646&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85064978646&partnerID=8YFLogxK

U2 - 10.1039/c9lc00115h

DO - 10.1039/c9lc00115h

M3 - Article

C2 - 30942226

AN - SCOPUS:85064978646

VL - 19

SP - 1676

EP - 1685

JO - Lab on a Chip - Miniaturisation for Chemistry and Biology

JF - Lab on a Chip - Miniaturisation for Chemistry and Biology

SN - 1473-0197

IS - 9

ER -