The design and manufacturing of new micro nebulizer

Sheng-Chih Shen, S. N. Liou, Y. R. Wang, C. P. Chien, Y. C. Chen, C. S. Yen, I. K. Pan, C. J. Lee, C. W. Yang, M. R. Wang

研究成果: Conference contribution

摘要

The application of spray device to treat respiratory disease has been effective for a long time. Moreover, the clinical studies show that if the droplet size is finer, the deeper position of the trachea could be reached. With an eye on enhancing the curative effect, this paper proposed a novel nebulizer integrating the piezoelectric actuator, micro nozzle plate, and the cavity of micro pump to achieve high-quality atomizing effect. According to the simulations and the experiments, it can be inferred that the droplet size distribution of the nebulizer in this research is finer and more uniform than the conventional ones. Furthermore, the system power consumption is lower than the former ultrasonic type.

原文English
主出版物標題2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004
頁面103-106
頁數4
出版狀態Published - 2004 十二月 1
事件2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004 - Hong Kong, China
持續時間: 2004 六月 262004 七月 2

出版系列

名字2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004

Other

Other2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004
國家China
城市Hong Kong
期間04-06-2604-07-02

指紋

Nebulizers and Vaporizers
Pulmonary diseases
Piezoelectric actuators
Trachea
Ultrasonics
Nozzles
Electric power utilization
Pumps
Equipment and Supplies
Research
Experiments
Clinical Studies

All Science Journal Classification (ASJC) codes

  • Mechanical Engineering
  • Materials Science(all)
  • Medicine(all)

引用此文

Shen, S-C., Liou, S. N., Wang, Y. R., Chien, C. P., Chen, Y. C., Yen, C. S., ... Wang, M. R. (2004). The design and manufacturing of new micro nebulizer. 於 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004 (頁 103-106). [1689573] (2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004).
Shen, Sheng-Chih ; Liou, S. N. ; Wang, Y. R. ; Chien, C. P. ; Chen, Y. C. ; Yen, C. S. ; Pan, I. K. ; Lee, C. J. ; Yang, C. W. ; Wang, M. R. / The design and manufacturing of new micro nebulizer. 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004. 2004. 頁 103-106 (2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004).
@inproceedings{90b79354cf9841e791d702b6c5a317d0,
title = "The design and manufacturing of new micro nebulizer",
abstract = "The application of spray device to treat respiratory disease has been effective for a long time. Moreover, the clinical studies show that if the droplet size is finer, the deeper position of the trachea could be reached. With an eye on enhancing the curative effect, this paper proposed a novel nebulizer integrating the piezoelectric actuator, micro nozzle plate, and the cavity of micro pump to achieve high-quality atomizing effect. According to the simulations and the experiments, it can be inferred that the droplet size distribution of the nebulizer in this research is finer and more uniform than the conventional ones. Furthermore, the system power consumption is lower than the former ultrasonic type.",
author = "Sheng-Chih Shen and Liou, {S. N.} and Wang, {Y. R.} and Chien, {C. P.} and Chen, {Y. C.} and Yen, {C. S.} and Pan, {I. K.} and Lee, {C. J.} and Yang, {C. W.} and Wang, {M. R.}",
year = "2004",
month = "12",
day = "1",
language = "English",
isbn = "0780386124",
series = "2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004",
pages = "103--106",
booktitle = "2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004",

}

Shen, S-C, Liou, SN, Wang, YR, Chien, CP, Chen, YC, Yen, CS, Pan, IK, Lee, CJ, Yang, CW & Wang, MR 2004, The design and manufacturing of new micro nebulizer. 於 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004., 1689573, 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004, 頁 103-106, 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004, Hong Kong, China, 04-06-26.

The design and manufacturing of new micro nebulizer. / Shen, Sheng-Chih; Liou, S. N.; Wang, Y. R.; Chien, C. P.; Chen, Y. C.; Yen, C. S.; Pan, I. K.; Lee, C. J.; Yang, C. W.; Wang, M. R.

2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004. 2004. p. 103-106 1689573 (2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004).

研究成果: Conference contribution

TY - GEN

T1 - The design and manufacturing of new micro nebulizer

AU - Shen, Sheng-Chih

AU - Liou, S. N.

AU - Wang, Y. R.

AU - Chien, C. P.

AU - Chen, Y. C.

AU - Yen, C. S.

AU - Pan, I. K.

AU - Lee, C. J.

AU - Yang, C. W.

AU - Wang, M. R.

PY - 2004/12/1

Y1 - 2004/12/1

N2 - The application of spray device to treat respiratory disease has been effective for a long time. Moreover, the clinical studies show that if the droplet size is finer, the deeper position of the trachea could be reached. With an eye on enhancing the curative effect, this paper proposed a novel nebulizer integrating the piezoelectric actuator, micro nozzle plate, and the cavity of micro pump to achieve high-quality atomizing effect. According to the simulations and the experiments, it can be inferred that the droplet size distribution of the nebulizer in this research is finer and more uniform than the conventional ones. Furthermore, the system power consumption is lower than the former ultrasonic type.

AB - The application of spray device to treat respiratory disease has been effective for a long time. Moreover, the clinical studies show that if the droplet size is finer, the deeper position of the trachea could be reached. With an eye on enhancing the curative effect, this paper proposed a novel nebulizer integrating the piezoelectric actuator, micro nozzle plate, and the cavity of micro pump to achieve high-quality atomizing effect. According to the simulations and the experiments, it can be inferred that the droplet size distribution of the nebulizer in this research is finer and more uniform than the conventional ones. Furthermore, the system power consumption is lower than the former ultrasonic type.

UR - http://www.scopus.com/inward/record.url?scp=34547369621&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34547369621&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:34547369621

SN - 0780386124

SN - 9780780386129

T3 - 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004

SP - 103

EP - 106

BT - 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004

ER -

Shen S-C, Liou SN, Wang YR, Chien CP, Chen YC, Yen CS 等. The design and manufacturing of new micro nebulizer. 於 2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004. 2004. p. 103-106. 1689573. (2004 2nd IEEE/EMBS International Summer School on Medical Devices and Biosensors, ISSS-MDBS 2004).