TY - JOUR
T1 - Trans-Endplate Pedicle Pillar System in unstable spinal burst fractures
T2 - Design, technique, and mechanical evaluation
AU - Zhao, Chunfeng
AU - Hongo, Michio
AU - Ilharreborde, Brice
AU - Zhao, Kristin D.
AU - Currier, Bradford L.
AU - An, Kai Nan
N1 - Funding Information:
This study was funded by Mayo Foundation. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Publisher Copyright:
© 2015 Zhao et al This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2015/10/26
Y1 - 2015/10/26
N2 - Background: Short-segment pedicle screw instrumentation (SSPI) is used for unstable burst fractures to correct deformity and stabilize the spine for fusion. However, pedicle screw loosening, pullout, or breakage often occurs due to the large moment applied during spine motion, leading to poor outcomes. The purpose of this study was to test the ability of a newly designed device, the Trans-Endplate Pedicle Pillar System (TEPPS), to enhance SSPI rigidity and decrease the screw bending moment with a simple posterior approach. Methods: Six human cadaveric spines (T11-L3) were harvested. A burst fracture was created at L1, and the SSPI (Moss Miami System) was used for SSPI fixation. Strain gauge sensors were mounted on upper pedicle screws tomeasure screw load bearing. Segmental motion (T12-L2) was measured under pure moment of 7.5 Nm. The spine was tested sequentially under 4 conditions: intact; first SSPI alone (SSPI-1); SSPI+TEPPS; and second SSPI alone (SSPI-2). Results: SSPI+TEPPS increased fixation rigidity by 41% in flexion/extension, 28% in lateral bending, and 37% in axial rotation compared with SSPI-1 (P<0.001), and it performed even better compared to SSPI-2 (P<0.001 for all). Importantly, the bending moment on the pedicle screws for SSPI+TEPPS was significantly decreased 63% during spine flexion and 47% in lateral bending (p<0.001). Conclusion: TEPPS provided strong anterior support, enhanced SSPI fixation rigidity, and dramatically decreased the load on the pedicle screws. Its biomechanical benefits could potentially improve fusion rates and decrease SSPI instrumentation failure.
AB - Background: Short-segment pedicle screw instrumentation (SSPI) is used for unstable burst fractures to correct deformity and stabilize the spine for fusion. However, pedicle screw loosening, pullout, or breakage often occurs due to the large moment applied during spine motion, leading to poor outcomes. The purpose of this study was to test the ability of a newly designed device, the Trans-Endplate Pedicle Pillar System (TEPPS), to enhance SSPI rigidity and decrease the screw bending moment with a simple posterior approach. Methods: Six human cadaveric spines (T11-L3) were harvested. A burst fracture was created at L1, and the SSPI (Moss Miami System) was used for SSPI fixation. Strain gauge sensors were mounted on upper pedicle screws tomeasure screw load bearing. Segmental motion (T12-L2) was measured under pure moment of 7.5 Nm. The spine was tested sequentially under 4 conditions: intact; first SSPI alone (SSPI-1); SSPI+TEPPS; and second SSPI alone (SSPI-2). Results: SSPI+TEPPS increased fixation rigidity by 41% in flexion/extension, 28% in lateral bending, and 37% in axial rotation compared with SSPI-1 (P<0.001), and it performed even better compared to SSPI-2 (P<0.001 for all). Importantly, the bending moment on the pedicle screws for SSPI+TEPPS was significantly decreased 63% during spine flexion and 47% in lateral bending (p<0.001). Conclusion: TEPPS provided strong anterior support, enhanced SSPI fixation rigidity, and dramatically decreased the load on the pedicle screws. Its biomechanical benefits could potentially improve fusion rates and decrease SSPI instrumentation failure.
UR - http://www.scopus.com/inward/record.url?scp=84949478111&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84949478111&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0139592
DO - 10.1371/journal.pone.0139592
M3 - Article
C2 - 26502352
AN - SCOPUS:84949478111
SN - 1932-6203
VL - 10
JO - PloS one
JF - PloS one
IS - 10
M1 - e0139592
ER -