Ultrasonography applied in guiding the reduction and assessing the healing of distal humeral epiphysis fracture-separation in a neonate-A case report

Ping Hui Wang, Tai Chang Chern, Wei-Ren Su, I. Ming Jou

研究成果: Article

1 引文 (Scopus)

摘要

Fracture-separation of the distal humeral epiphysis is a relatively rare injury in neonates and might occur as a complication of difficult deliveries. Fracture in skeletally immature children is often difficult to assess on plain radiographs, and more so in neonates or in the meta- and epiphysis areas where secondary ossification centers are absent. We described the case of a neonate with a type 1 Salter-Harris fracture of the distal humerus following uncomplicated labor of vaginal delivery without instrument use. The baby presented with gross elbow swelling that was accurately diagnosed with ultrasonography as a posterolateral displacement of the epiphysis which was not apparent on plain radiography and was further confirmed by MRI and intraoperative findings. The fractured distal humerus was reduced by percutaneous reduction after several attempts at close reduction. Serial follow-up ultrasonographies revealed good reduction and healing. In a final examination at age 4 years, the child had no residual deformity and normal range of motion.

原文English
期刊European Journal of Radiology Extra
72
發行號2
DOIs
出版狀態Published - 2009 十一月 1

指紋

Humeral Fractures
Epiphyses
Ultrasonography
Humerus
Newborn Infant
Elbow
Articular Range of Motion
Osteogenesis
Radiography
Reference Values
Wounds and Injuries

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

引用此文

@article{500fe9281bde495e87e443a9edb10793,
title = "Ultrasonography applied in guiding the reduction and assessing the healing of distal humeral epiphysis fracture-separation in a neonate-A case report",
abstract = "Fracture-separation of the distal humeral epiphysis is a relatively rare injury in neonates and might occur as a complication of difficult deliveries. Fracture in skeletally immature children is often difficult to assess on plain radiographs, and more so in neonates or in the meta- and epiphysis areas where secondary ossification centers are absent. We described the case of a neonate with a type 1 Salter-Harris fracture of the distal humerus following uncomplicated labor of vaginal delivery without instrument use. The baby presented with gross elbow swelling that was accurately diagnosed with ultrasonography as a posterolateral displacement of the epiphysis which was not apparent on plain radiography and was further confirmed by MRI and intraoperative findings. The fractured distal humerus was reduced by percutaneous reduction after several attempts at close reduction. Serial follow-up ultrasonographies revealed good reduction and healing. In a final examination at age 4 years, the child had no residual deformity and normal range of motion.",
author = "Wang, {Ping Hui} and Chern, {Tai Chang} and Wei-Ren Su and Jou, {I. Ming}",
year = "2009",
month = "11",
day = "1",
doi = "10.1016/j.ejrex.2009.06.009",
language = "English",
volume = "72",
journal = "European Journal of Radiology Extra",
issn = "1571-4675",
publisher = "Elsevier BV",
number = "2",

}

TY - JOUR

T1 - Ultrasonography applied in guiding the reduction and assessing the healing of distal humeral epiphysis fracture-separation in a neonate-A case report

AU - Wang, Ping Hui

AU - Chern, Tai Chang

AU - Su, Wei-Ren

AU - Jou, I. Ming

PY - 2009/11/1

Y1 - 2009/11/1

N2 - Fracture-separation of the distal humeral epiphysis is a relatively rare injury in neonates and might occur as a complication of difficult deliveries. Fracture in skeletally immature children is often difficult to assess on plain radiographs, and more so in neonates or in the meta- and epiphysis areas where secondary ossification centers are absent. We described the case of a neonate with a type 1 Salter-Harris fracture of the distal humerus following uncomplicated labor of vaginal delivery without instrument use. The baby presented with gross elbow swelling that was accurately diagnosed with ultrasonography as a posterolateral displacement of the epiphysis which was not apparent on plain radiography and was further confirmed by MRI and intraoperative findings. The fractured distal humerus was reduced by percutaneous reduction after several attempts at close reduction. Serial follow-up ultrasonographies revealed good reduction and healing. In a final examination at age 4 years, the child had no residual deformity and normal range of motion.

AB - Fracture-separation of the distal humeral epiphysis is a relatively rare injury in neonates and might occur as a complication of difficult deliveries. Fracture in skeletally immature children is often difficult to assess on plain radiographs, and more so in neonates or in the meta- and epiphysis areas where secondary ossification centers are absent. We described the case of a neonate with a type 1 Salter-Harris fracture of the distal humerus following uncomplicated labor of vaginal delivery without instrument use. The baby presented with gross elbow swelling that was accurately diagnosed with ultrasonography as a posterolateral displacement of the epiphysis which was not apparent on plain radiography and was further confirmed by MRI and intraoperative findings. The fractured distal humerus was reduced by percutaneous reduction after several attempts at close reduction. Serial follow-up ultrasonographies revealed good reduction and healing. In a final examination at age 4 years, the child had no residual deformity and normal range of motion.

UR - http://www.scopus.com/inward/record.url?scp=70350619482&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350619482&partnerID=8YFLogxK

U2 - 10.1016/j.ejrex.2009.06.009

DO - 10.1016/j.ejrex.2009.06.009

M3 - Article

AN - SCOPUS:70350619482

VL - 72

JO - European Journal of Radiology Extra

JF - European Journal of Radiology Extra

SN - 1571-4675

IS - 2

ER -