Ventilation pattern and heat dissipation characteristics of a vertical dry storage cask for spent nuclear fuel: Wind tunnel experiments and CFD simulations

Yao Hung Wang, Yi Pin Lin, Heui Yung Chang, Chi Ming Lai

研究成果: Article同行評審

1 引文 斯高帕斯(Scopus)

摘要

In this study, wind tunnel experiments and computational fluid dynamics (CFD) simulations were conducted to observe the channel airflow patterns and heat dissipation characteristics of dry storage casks for spent nuclear fuel. The parameter ranges were as follows: model scale = 1/10, Grashof number (Gr) = 1.0 × 1011, approaching wind angle (θ) = 0° or 45°, and Reynolds number (Re) = 2.6×104-8.0×105. The results show that a wind velocity = 3 m/s (Re = 8 × 104) is a critical condition for the channel airflow pattern inside the cask for cases in which θ = 0°. When θ = 45°, different wind velocities result in similar channel airflow patterns. As the wind velocity increases, the overall average surface temperature of the canister decreases, and the decrease lessens as the wind velocity increases.

原文English
文章編號108364
期刊Annals of Nuclear Energy
160
DOIs
出版狀態Published - 2021 九月 15

All Science Journal Classification (ASJC) codes

  • 核能與工程

指紋

深入研究「Ventilation pattern and heat dissipation characteristics of a vertical dry storage cask for spent nuclear fuel: Wind tunnel experiments and CFD simulations」主題。共同形成了獨特的指紋。